ABAP Select data from SAP table V_74FH_F into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_74FH_F table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_74FH_F. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_74FH_F table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_74FH_F TYPE STANDARD TABLE OF V_74FH_F, WA_V_74FH_F TYPE V_74FH_F, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_74FH_F> TYPE V_74FH_F. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_74FH_F. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_74FH_F INTO TABLE IT_V_74FH_F. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_74FH_F * INTO TABLE @DATA(IT_V_74FH_F2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_74FH_F INDEX 1 INTO DATA(WA_V_74FH_F2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_74FH_F ASSIGNING <V_74FH_F>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_74FH_F>-MANDT = 1.
<V_74FH_F>-BAREA = 1.
<V_74FH_F>-BPLAN = 1.
<V_74FH_F>-EECON = 1.
<V_74FH_F>-SALGR = 1.
ENDLOOP. LOOP AT IT_V_74FH_F INTO WA_V_74FH_F. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_74FH_F-AGEGR, sy-vline,
WA_V_74FH_F-LOSGR, sy-vline,
WA_V_74FH_F-EECGR, sy-vline,
WA_V_74FH_F-ENDDA, sy-vline,
WA_V_74FH_F-PLNTX, sy-vline,
WA_V_74FH_F-PERIO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_74FH_F you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_74FH_F TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_74FH_F INTO WA_V_74FH_F. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_74FH_F_STR,
MANDT TYPE STRING,
BAREA TYPE STRING,
BPLAN TYPE STRING,
EECON TYPE STRING,
SALGR TYPE STRING,
AGEGR TYPE STRING,
LOSGR TYPE STRING,
EECGR TYPE STRING,
ENDDA TYPE STRING,
PLNTX TYPE STRING,
PERIO TYPE STRING,
EECIN TYPE STRING,
SALIN TYPE STRING,
AGEIN TYPE STRING,
LOSIN TYPE STRING,
CRGRP TYPE STRING,
BEGDA TYPE STRING,
CMINA TYPE STRING,
CMAXA TYPE STRING,
PMINA TYPE STRING,
PMAXA TYPE STRING,
CMINP TYPE STRING,
CMAXP TYPE STRING,
PMINP TYPE STRING,
PMAXP TYPE STRING,
PCTOK TYPE STRING,
AMTOK TYPE STRING,
PREOK TYPE STRING,
PSTOK TYPE STRING,
LIMIT TYPE STRING,
UNTOK TYPE STRING,
BPROK TYPE STRING,
BPTOK TYPE STRING,
CMINU TYPE STRING,
CMAXU TYPE STRING,
PMINU TYPE STRING,
PMAXU TYPE STRING,
PTLIM TYPE STRING,
TLLIM TYPE STRING,
BCMIA TYPE STRING,
BCMAA TYPE STRING,
BCMIP TYPE STRING,
BCMAP TYPE STRING,
BCMIU TYPE STRING,
BCMAU TYPE STRING,
BPMIA TYPE STRING,
BPMAA TYPE STRING,
BPMIP TYPE STRING,
BPMAP TYPE STRING,
BPMIU TYPE STRING,
BPMAU TYPE STRING,
EECRL TYPE STRING,
EECRN TYPE STRING,
EEGTX TYPE STRING,
EECTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_74FH_F_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_74FH_F_STR-MANDT sy-vline
WA_V_74FH_F_STR-BAREA sy-vline
WA_V_74FH_F_STR-BPLAN sy-vline
WA_V_74FH_F_STR-EECON sy-vline
WA_V_74FH_F_STR-SALGR sy-vline
WA_V_74FH_F_STR-AGEGR sy-vline
WA_V_74FH_F_STR-LOSGR sy-vline
WA_V_74FH_F_STR-EECGR sy-vline
WA_V_74FH_F_STR-ENDDA sy-vline
WA_V_74FH_F_STR-PLNTX sy-vline
WA_V_74FH_F_STR-PERIO sy-vline
WA_V_74FH_F_STR-EECIN sy-vline
WA_V_74FH_F_STR-SALIN sy-vline
WA_V_74FH_F_STR-AGEIN sy-vline
WA_V_74FH_F_STR-LOSIN sy-vline
WA_V_74FH_F_STR-CRGRP sy-vline
WA_V_74FH_F_STR-BEGDA sy-vline
WA_V_74FH_F_STR-CMINA sy-vline
WA_V_74FH_F_STR-CMAXA sy-vline
WA_V_74FH_F_STR-PMINA sy-vline
WA_V_74FH_F_STR-PMAXA sy-vline
WA_V_74FH_F_STR-CMINP sy-vline
WA_V_74FH_F_STR-CMAXP sy-vline
WA_V_74FH_F_STR-PMINP sy-vline
WA_V_74FH_F_STR-PMAXP sy-vline
WA_V_74FH_F_STR-PCTOK sy-vline
WA_V_74FH_F_STR-AMTOK sy-vline
WA_V_74FH_F_STR-PREOK sy-vline
WA_V_74FH_F_STR-PSTOK sy-vline
WA_V_74FH_F_STR-LIMIT sy-vline
WA_V_74FH_F_STR-UNTOK sy-vline
WA_V_74FH_F_STR-BPROK sy-vline
WA_V_74FH_F_STR-BPTOK sy-vline
WA_V_74FH_F_STR-CMINU sy-vline
WA_V_74FH_F_STR-CMAXU sy-vline
WA_V_74FH_F_STR-PMINU sy-vline
WA_V_74FH_F_STR-PMAXU sy-vline
WA_V_74FH_F_STR-PTLIM sy-vline
WA_V_74FH_F_STR-TLLIM sy-vline
WA_V_74FH_F_STR-BCMIA sy-vline
WA_V_74FH_F_STR-BCMAA sy-vline
WA_V_74FH_F_STR-BCMIP sy-vline
WA_V_74FH_F_STR-BCMAP sy-vline
WA_V_74FH_F_STR-BCMIU sy-vline
WA_V_74FH_F_STR-BCMAU sy-vline
WA_V_74FH_F_STR-BPMIA sy-vline
WA_V_74FH_F_STR-BPMAA sy-vline
WA_V_74FH_F_STR-BPMIP sy-vline
WA_V_74FH_F_STR-BPMAP sy-vline
WA_V_74FH_F_STR-BPMIU sy-vline
WA_V_74FH_F_STR-BPMAU sy-vline
WA_V_74FH_F_STR-EECRL sy-vline
WA_V_74FH_F_STR-EECRN sy-vline
WA_V_74FH_F_STR-EEGTX sy-vline
WA_V_74FH_F_STR-EECTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.