ABAP Select data from SAP table V_7CN20_PHF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_7CN20_PHF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_7CN20_PHF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_7CN20_PHF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_7CN20_PHF TYPE STANDARD TABLE OF V_7CN20_PHF,
      WA_V_7CN20_PHF TYPE V_7CN20_PHF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_7CN20_PHF> TYPE V_7CN20_PHF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_7CN20_PHF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_7CN20_PHF
  INTO TABLE IT_V_7CN20_PHF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_7CN20_PHF
*  INTO TABLE @DATA(IT_V_7CN20_PHF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_7CN20_PHF INDEX 1 INTO DATA(WA_V_7CN20_PHF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_7CN20_PHF ASSIGNING <V_7CN20_PHF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_7CN20_PHF>-MANDT = 1.
<V_7CN20_PHF>-INFTY = 1.
<V_7CN20_PHF>-INTYP = 1.
<V_7CN20_PHF>-CONBR = 1.
<V_7CN20_PHF>-CONAR = 1.
ENDLOOP.

LOOP AT IT_V_7CN20_PHF INTO WA_V_7CN20_PHF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_7CN20_PHF-CONGR, sy-vline,
WA_V_7CN20_PHF-CONLV, sy-vline,
WA_V_7CN20_PHF-PASSR, sy-vline,
WA_V_7CN20_PHF-ENDDA, sy-vline,
WA_V_7CN20_PHF-BEGDA, sy-vline,
WA_V_7CN20_PHF-EEIND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_7CN20_PHF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_7CN20_PHF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_7CN20_PHF INTO WA_V_7CN20_PHF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_7CN20_PHF_STR,
MANDT TYPE STRING,
INFTY TYPE STRING,
INTYP TYPE STRING,
CONBR TYPE STRING,
CONAR TYPE STRING,
CONGR TYPE STRING,
CONLV TYPE STRING,
PASSR TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
EEIND TYPE STRING,
EERAT TYPE STRING,
EECON TYPE STRING,
ECCUR TYPE STRING,
EELOW TYPE STRING,
EELCU TYPE STRING,
EEHIG TYPE STRING,
EEHCU TYPE STRING,
ERIND TYPE STRING,
ERRAT TYPE STRING,
ERCON TYPE STRING,
RCCUR TYPE STRING,
ERLOW TYPE STRING,
ERLCU TYPE STRING,
ERHIG TYPE STRING,
ERHCU TYPE STRING,
TYTXT TYPE STRING,
ARTXT TYPE STRING,
EEWGE TYPE STRING,
ERWGE TYPE STRING,
EEBSR TYPE STRING,
EECOR TYPE STRING,
ERBSR TYPE STRING,
ERCOR TYPE STRING,
ERDIF TYPE STRING,
EMRAT TYPE STRING,
EMMTP TYPE STRING,
EMAVG TYPE STRING,
EXMTH TYPE STRING,
EXBSR TYPE STRING,
EXCOR TYPE STRING,
EEEMP TYPE STRING,
EEECU TYPE STRING,
EREMP TYPE STRING,
ERECU TYPE STRING,
CONGRT TYPE STRING,
CONLVT TYPE STRING,
EXMPT_RATE_EE TYPE STRING,
EXMPT_RATE_ER TYPE STRING,
DIFF_EXMPT_EE_ER TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_7CN20_PHF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_7CN20_PHF_STR-MANDT sy-vline
WA_V_7CN20_PHF_STR-INFTY sy-vline
WA_V_7CN20_PHF_STR-INTYP sy-vline
WA_V_7CN20_PHF_STR-CONBR sy-vline
WA_V_7CN20_PHF_STR-CONAR sy-vline
WA_V_7CN20_PHF_STR-CONGR sy-vline
WA_V_7CN20_PHF_STR-CONLV sy-vline
WA_V_7CN20_PHF_STR-PASSR sy-vline
WA_V_7CN20_PHF_STR-ENDDA sy-vline
WA_V_7CN20_PHF_STR-BEGDA sy-vline
WA_V_7CN20_PHF_STR-EEIND sy-vline
WA_V_7CN20_PHF_STR-EERAT sy-vline
WA_V_7CN20_PHF_STR-EECON sy-vline
WA_V_7CN20_PHF_STR-ECCUR sy-vline
WA_V_7CN20_PHF_STR-EELOW sy-vline
WA_V_7CN20_PHF_STR-EELCU sy-vline
WA_V_7CN20_PHF_STR-EEHIG sy-vline
WA_V_7CN20_PHF_STR-EEHCU sy-vline
WA_V_7CN20_PHF_STR-ERIND sy-vline
WA_V_7CN20_PHF_STR-ERRAT sy-vline
WA_V_7CN20_PHF_STR-ERCON sy-vline
WA_V_7CN20_PHF_STR-RCCUR sy-vline
WA_V_7CN20_PHF_STR-ERLOW sy-vline
WA_V_7CN20_PHF_STR-ERLCU sy-vline
WA_V_7CN20_PHF_STR-ERHIG sy-vline
WA_V_7CN20_PHF_STR-ERHCU sy-vline
WA_V_7CN20_PHF_STR-TYTXT sy-vline
WA_V_7CN20_PHF_STR-ARTXT sy-vline
WA_V_7CN20_PHF_STR-EEWGE sy-vline
WA_V_7CN20_PHF_STR-ERWGE sy-vline
WA_V_7CN20_PHF_STR-EEBSR sy-vline
WA_V_7CN20_PHF_STR-EECOR sy-vline
WA_V_7CN20_PHF_STR-ERBSR sy-vline
WA_V_7CN20_PHF_STR-ERCOR sy-vline
WA_V_7CN20_PHF_STR-ERDIF sy-vline
WA_V_7CN20_PHF_STR-EMRAT sy-vline
WA_V_7CN20_PHF_STR-EMMTP sy-vline
WA_V_7CN20_PHF_STR-EMAVG sy-vline
WA_V_7CN20_PHF_STR-EXMTH sy-vline
WA_V_7CN20_PHF_STR-EXBSR sy-vline
WA_V_7CN20_PHF_STR-EXCOR sy-vline
WA_V_7CN20_PHF_STR-EEEMP sy-vline
WA_V_7CN20_PHF_STR-EEECU sy-vline
WA_V_7CN20_PHF_STR-EREMP sy-vline
WA_V_7CN20_PHF_STR-ERECU sy-vline
WA_V_7CN20_PHF_STR-CONGRT sy-vline
WA_V_7CN20_PHF_STR-CONLVT sy-vline
WA_V_7CN20_PHF_STR-EXMPT_RATE_EE sy-vline
WA_V_7CN20_PHF_STR-EXMPT_RATE_ER sy-vline
WA_V_7CN20_PHF_STR-DIFF_EXMPT_EE_ER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.