ABAP Select data from SAP table V_BUAVCTOLASS_CT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_BUAVCTOLASS_CT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_BUAVCTOLASS_CT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_BUAVCTOLASS_CT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_BUAVCTOLASS_CT TYPE STANDARD TABLE OF V_BUAVCTOLASS_CT,
      WA_V_BUAVCTOLASS_CT TYPE V_BUAVCTOLASS_CT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_BUAVCTOLASS_CT> TYPE V_BUAVCTOLASS_CT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_BUAVCTOLASS_CT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_BUAVCTOLASS_CT
  INTO TABLE IT_V_BUAVCTOLASS_CT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_BUAVCTOLASS_CT
*  INTO TABLE @DATA(IT_V_BUAVCTOLASS_CT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_BUAVCTOLASS_CT INDEX 1 INTO DATA(WA_V_BUAVCTOLASS_CT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_BUAVCTOLASS_CT ASSIGNING <V_BUAVCTOLASS_CT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_BUAVCTOLASS_CT>-CLIENT = 1.
<V_BUAVCTOLASS_CT>-APPLIC = 1.
<V_BUAVCTOLASS_CT>-TOLPROF = 1.
<V_BUAVCTOLASS_CT>-CEILTYPE = 1.
<V_BUAVCTOLASS_CT>-ACTIVGRP = 1.
ENDLOOP.

LOOP AT IT_V_BUAVCTOLASS_CT INTO WA_V_BUAVCTOLASS_CT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_BUAVCTOLASS_CT-CHECK_ORDER, sy-vline,
WA_V_BUAVCTOLASS_CT-TOLPROFTEXT, sy-vline,
WA_V_BUAVCTOLASS_CT-ACTIVGRPTEXT, sy-vline,
WA_V_BUAVCTOLASS_CT-RELLIMIT, sy-vline,
WA_V_BUAVCTOLASS_CT-ABSVAR, sy-vline,
WA_V_BUAVCTOLASS_CT-CURRENCY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_BUAVCTOLASS_CT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_BUAVCTOLASS_CT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_BUAVCTOLASS_CT INTO WA_V_BUAVCTOLASS_CT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_BUAVCTOLASS_CT_STR,
CLIENT TYPE STRING,
APPLIC TYPE STRING,
TOLPROF TYPE STRING,
CEILTYPE TYPE STRING,
ACTIVGRP TYPE STRING,
CHECK_ORDER TYPE STRING,
TOLPROFTEXT TYPE STRING,
ACTIVGRPTEXT TYPE STRING,
RELLIMIT TYPE STRING,
ABSVAR TYPE STRING,
CURRENCY TYPE STRING,
TOLLIMUSE TYPE STRING,
MSGTY TYPE STRING,
EVENT TYPE STRING,
EVENTTEXT TYPE STRING,
DEACTIVE TYPE STRING,
TOLPROFCATEG TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_BUAVCTOLASS_CT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_BUAVCTOLASS_CT_STR-CLIENT sy-vline
WA_V_BUAVCTOLASS_CT_STR-APPLIC sy-vline
WA_V_BUAVCTOLASS_CT_STR-TOLPROF sy-vline
WA_V_BUAVCTOLASS_CT_STR-CEILTYPE sy-vline
WA_V_BUAVCTOLASS_CT_STR-ACTIVGRP sy-vline
WA_V_BUAVCTOLASS_CT_STR-CHECK_ORDER sy-vline
WA_V_BUAVCTOLASS_CT_STR-TOLPROFTEXT sy-vline
WA_V_BUAVCTOLASS_CT_STR-ACTIVGRPTEXT sy-vline
WA_V_BUAVCTOLASS_CT_STR-RELLIMIT sy-vline
WA_V_BUAVCTOLASS_CT_STR-ABSVAR sy-vline
WA_V_BUAVCTOLASS_CT_STR-CURRENCY sy-vline
WA_V_BUAVCTOLASS_CT_STR-TOLLIMUSE sy-vline
WA_V_BUAVCTOLASS_CT_STR-MSGTY sy-vline
WA_V_BUAVCTOLASS_CT_STR-EVENT sy-vline
WA_V_BUAVCTOLASS_CT_STR-EVENTTEXT sy-vline
WA_V_BUAVCTOLASS_CT_STR-DEACTIVE sy-vline
WA_V_BUAVCTOLASS_CT_STR-TOLPROFCATEG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.