ABAP Select data from SAP table V_ICLCCEVENT_HIL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_ICLCCEVENT_HIL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_ICLCCEVENT_HIL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_ICLCCEVENT_HIL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_ICLCCEVENT_HIL TYPE STANDARD TABLE OF V_ICLCCEVENT_HIL, WA_V_ICLCCEVENT_HIL TYPE V_ICLCCEVENT_HIL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_ICLCCEVENT_HIL> TYPE V_ICLCCEVENT_HIL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_ICLCCEVENT_HIL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_ICLCCEVENT_HIL INTO TABLE IT_V_ICLCCEVENT_HIL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_ICLCCEVENT_HIL * INTO TABLE @DATA(IT_V_ICLCCEVENT_HIL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_ICLCCEVENT_HIL INDEX 1 INTO DATA(WA_V_ICLCCEVENT_HIL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_ICLCCEVENT_HIL ASSIGNING <V_ICLCCEVENT_HIL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_ICLCCEVENT_HIL>-CLIENT = 1.
<V_ICLCCEVENT_HIL>-ACTIVE = 1.
<V_ICLCCEVENT_HIL>-CCEVENT = 1.
<V_ICLCCEVENT_HIL>-CCTYPE = 1.
<V_ICLCCEVENT_HIL>-CCTYPEN = 1.
ENDLOOP. LOOP AT IT_V_ICLCCEVENT_HIL INTO WA_V_ICLCCEVENT_HIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_ICLCCEVENT_HIL-TYPE, sy-vline,
WA_V_ICLCCEVENT_HIL-SUBTYPE, sy-vline,
WA_V_ICLCCEVENT_HIL-SUBTYPENAME, sy-vline,
WA_V_ICLCCEVENT_HIL-RANGEFROM, sy-vline,
WA_V_ICLCCEVENT_HIL-STATUS, sy-vline,
WA_V_ICLCCEVENT_HIL-CCSBRTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_ICLCCEVENT_HIL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_ICLCCEVENT_HIL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_ICLCCEVENT_HIL INTO WA_V_ICLCCEVENT_HIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field CCEVENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_ICLCCEVENT_HIL-CCEVENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_ICLCCEVENT_HIL-CCEVENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_V_ICLCCEVENT_HIL-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_ICLCCEVENT_HIL-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_ICLCCEVENT_HIL_STR,
CLIENT TYPE STRING,
ACTIVE TYPE STRING,
CCEVENT TYPE STRING,
CCTYPE TYPE STRING,
CCTYPEN TYPE STRING,
TYPE TYPE STRING,
SUBTYPE TYPE STRING,
SUBTYPENAME TYPE STRING,
RANGEFROM TYPE STRING,
STATUS TYPE STRING,
CCSBRTYPE TYPE STRING,
LANGU TYPE STRING,
CREATEDBY TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_ICLCCEVENT_HIL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_ICLCCEVENT_HIL_STR-CLIENT sy-vline
WA_V_ICLCCEVENT_HIL_STR-ACTIVE sy-vline
WA_V_ICLCCEVENT_HIL_STR-CCEVENT sy-vline
WA_V_ICLCCEVENT_HIL_STR-CCTYPE sy-vline
WA_V_ICLCCEVENT_HIL_STR-CCTYPEN sy-vline
WA_V_ICLCCEVENT_HIL_STR-TYPE sy-vline
WA_V_ICLCCEVENT_HIL_STR-SUBTYPE sy-vline
WA_V_ICLCCEVENT_HIL_STR-SUBTYPENAME sy-vline
WA_V_ICLCCEVENT_HIL_STR-RANGEFROM sy-vline
WA_V_ICLCCEVENT_HIL_STR-STATUS sy-vline
WA_V_ICLCCEVENT_HIL_STR-CCSBRTYPE sy-vline
WA_V_ICLCCEVENT_HIL_STR-LANGU sy-vline
WA_V_ICLCCEVENT_HIL_STR-CREATEDBY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.