ABAP Select data from SAP table V_OIRAPROCDEF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_OIRAPROCDEF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_OIRAPROCDEF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_OIRAPROCDEF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_OIRAPROCDEF TYPE STANDARD TABLE OF V_OIRAPROCDEF, WA_V_OIRAPROCDEF TYPE V_OIRAPROCDEF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_OIRAPROCDEF> TYPE V_OIRAPROCDEF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_OIRAPROCDEF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_OIRAPROCDEF INTO TABLE IT_V_OIRAPROCDEF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_OIRAPROCDEF * INTO TABLE @DATA(IT_V_OIRAPROCDEF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_OIRAPROCDEF INDEX 1 INTO DATA(WA_V_OIRAPROCDEF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_OIRAPROCDEF ASSIGNING <V_OIRAPROCDEF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_OIRAPROCDEF>-PROCDEF = 1.
<V_OIRAPROCDEF>-PROCROUT = 1.
<V_OIRAPROCDEF>-UPDROUT = 1.
<V_OIRAPROCDEF>-DATEROUT = 1.
<V_OIRAPROCDEF>-RETEN_TIME = 1.
ENDLOOP. LOOP AT IT_V_OIRAPROCDEF INTO WA_V_OIRAPROCDEF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_OIRAPROCDEF-DEL_BEFORE, sy-vline,
WA_V_OIRAPROCDEF-USEREXITP, sy-vline,
WA_V_OIRAPROCDEF-USEREXITF, sy-vline,
WA_V_OIRAPROCDEF-DESCRIPTION, sy-vline,
WA_V_OIRAPROCDEF-DESCR_DAT, sy-vline,
WA_V_OIRAPROCDEF-DESCR_EXE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_OIRAPROCDEF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_OIRAPROCDEF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_OIRAPROCDEF INTO WA_V_OIRAPROCDEF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_OIRAPROCDEF_STR,
PROCDEF TYPE STRING,
PROCROUT TYPE STRING,
UPDROUT TYPE STRING,
DATEROUT TYPE STRING,
RETEN_TIME TYPE STRING,
DEL_BEFORE TYPE STRING,
USEREXITP TYPE STRING,
USEREXITF TYPE STRING,
DESCRIPTION TYPE STRING,
DESCR_DAT TYPE STRING,
DESCR_EXE TYPE STRING,
DESCR_GRPCHK TYPE STRING,
DESCR_UPD TYPE STRING,
GRP_CHKROUT TYPE STRING,
OBJECT_TYPE TYPE STRING,
DESCR_OBJ TYPE STRING,
PARA_PROC_ALLOW TYPE STRING,
PRINTPROC TYPE STRING,
PROCDESCR TYPE STRING,
AFTER_ROUT TYPE STRING,
DESCR_AFTER TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_OIRAPROCDEF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_OIRAPROCDEF_STR-PROCDEF sy-vline
WA_V_OIRAPROCDEF_STR-PROCROUT sy-vline
WA_V_OIRAPROCDEF_STR-UPDROUT sy-vline
WA_V_OIRAPROCDEF_STR-DATEROUT sy-vline
WA_V_OIRAPROCDEF_STR-RETEN_TIME sy-vline
WA_V_OIRAPROCDEF_STR-DEL_BEFORE sy-vline
WA_V_OIRAPROCDEF_STR-USEREXITP sy-vline
WA_V_OIRAPROCDEF_STR-USEREXITF sy-vline
WA_V_OIRAPROCDEF_STR-DESCRIPTION sy-vline
WA_V_OIRAPROCDEF_STR-DESCR_DAT sy-vline
WA_V_OIRAPROCDEF_STR-DESCR_EXE sy-vline
WA_V_OIRAPROCDEF_STR-DESCR_GRPCHK sy-vline
WA_V_OIRAPROCDEF_STR-DESCR_UPD sy-vline
WA_V_OIRAPROCDEF_STR-GRP_CHKROUT sy-vline
WA_V_OIRAPROCDEF_STR-OBJECT_TYPE sy-vline
WA_V_OIRAPROCDEF_STR-DESCR_OBJ sy-vline
WA_V_OIRAPROCDEF_STR-PARA_PROC_ALLOW sy-vline
WA_V_OIRAPROCDEF_STR-PRINTPROC sy-vline
WA_V_OIRAPROCDEF_STR-PROCDESCR sy-vline
WA_V_OIRAPROCDEF_STR-AFTER_ROUT sy-vline
WA_V_OIRAPROCDEF_STR-DESCR_AFTER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.