ABAP Select data from SAP table V_ORF5CUST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_ORF5CUST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_ORF5CUST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_ORF5CUST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_ORF5CUST TYPE STANDARD TABLE OF V_ORF5CUST,
      WA_V_ORF5CUST TYPE V_ORF5CUST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_ORF5CUST> TYPE V_ORF5CUST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_ORF5CUST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_ORF5CUST
  INTO TABLE IT_V_ORF5CUST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_ORF5CUST
*  INTO TABLE @DATA(IT_V_ORF5CUST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_ORF5CUST INDEX 1 INTO DATA(WA_V_ORF5CUST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_ORF5CUST ASSIGNING <V_ORF5CUST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_ORF5CUST>-MANDT = 1.
<V_ORF5CUST>-PROFL_ID = 1.
<V_ORF5CUST>-TEXT = 1.
<V_ORF5CUST>-TC_Q1 = 1.
<V_ORF5CUST>-TC_Q2 = 1.
ENDLOOP.

LOOP AT IT_V_ORF5CUST INTO WA_V_ORF5CUST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_ORF5CUST-TC_DEF, sy-vline,
WA_V_ORF5CUST-MTBE_Q1, sy-vline,
WA_V_ORF5CUST-MTBE_Q2, sy-vline,
WA_V_ORF5CUST-MTBE_DEF_OH, sy-vline,
WA_V_ORF5CUST-MTBE_DEF_LC, sy-vline,
WA_V_ORF5CUST-MTBE_DEF_OC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_ORF5CUST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_ORF5CUST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_ORF5CUST INTO WA_V_ORF5CUST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_ORF5CUST_STR,
MANDT TYPE STRING,
PROFL_ID TYPE STRING,
TEXT TYPE STRING,
TC_Q1 TYPE STRING,
TC_Q2 TYPE STRING,
TC_DEF TYPE STRING,
MTBE_Q1 TYPE STRING,
MTBE_Q2 TYPE STRING,
MTBE_DEF_OH TYPE STRING,
MTBE_DEF_LC TYPE STRING,
MTBE_DEF_OC TYPE STRING,
TAT_REP_Q1 TYPE STRING,
TAT_REP_Q2 TYPE STRING,
TAT_REP_DEF TYPE STRING,
TAT_TRP_Q1 TYPE STRING,
TAT_TRP_Q2 TYPE STRING,
TAT_TRP_DEF TYPE STRING,
EC_Q1 TYPE STRING,
EC_Q2 TYPE STRING,
EC_DEF TYPE STRING,
HS_Q1 TYPE STRING,
HS_Q2 TYPE STRING,
HS_DEF TYPE STRING,
PRICE_Q1 TYPE STRING,
PRICE_Q2 TYPE STRING,
PRICE_DEF TYPE STRING,
CURR_DEF TYPE STRING,
NFL_Q1 TYPE STRING,
NFL_Q2 TYPE STRING,
NFL_DEF TYPE STRING,
NEQ_Q1 TYPE STRING,
NEQ_Q2 TYPE STRING,
NEQ_DEF TYPE STRING,
TAU_Q1 TYPE STRING,
TAU_Q2 TYPE STRING,
TAU_DEF_OH TYPE STRING,
TAU_DEF_LC TYPE STRING,
TAU_DEF_OC TYPE STRING,
DD_DEF TYPE STRING,
SAVE_TYPE TYPE STRING,
CALC_TYPE2 TYPE STRING,
ROT_EXP_TYPE TYPE STRING,
MAD_TYPE TYPE STRING,
BATCH_DUM1 TYPE STRING,
BATCH_DUM2 TYPE STRING,
BATCH_DUM3 TYPE STRING,
SUPPL1 TYPE STRING,
WERKS TYPE STRING,
BWTAR TYPE STRING,
FLAG_NUM_BATCH TYPE STRING,
IP_MATNR_ASSIGN TYPE STRING,
DUMMY1 TYPE STRING,
DUMMY2 TYPE STRING,
DUMMY3 TYPE STRING,
DUMMY4 TYPE STRING,
DUMMY5 TYPE STRING,
DUMMY6 TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_ORF5CUST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_ORF5CUST_STR-MANDT sy-vline
WA_V_ORF5CUST_STR-PROFL_ID sy-vline
WA_V_ORF5CUST_STR-TEXT sy-vline
WA_V_ORF5CUST_STR-TC_Q1 sy-vline
WA_V_ORF5CUST_STR-TC_Q2 sy-vline
WA_V_ORF5CUST_STR-TC_DEF sy-vline
WA_V_ORF5CUST_STR-MTBE_Q1 sy-vline
WA_V_ORF5CUST_STR-MTBE_Q2 sy-vline
WA_V_ORF5CUST_STR-MTBE_DEF_OH sy-vline
WA_V_ORF5CUST_STR-MTBE_DEF_LC sy-vline
WA_V_ORF5CUST_STR-MTBE_DEF_OC sy-vline
WA_V_ORF5CUST_STR-TAT_REP_Q1 sy-vline
WA_V_ORF5CUST_STR-TAT_REP_Q2 sy-vline
WA_V_ORF5CUST_STR-TAT_REP_DEF sy-vline
WA_V_ORF5CUST_STR-TAT_TRP_Q1 sy-vline
WA_V_ORF5CUST_STR-TAT_TRP_Q2 sy-vline
WA_V_ORF5CUST_STR-TAT_TRP_DEF sy-vline
WA_V_ORF5CUST_STR-EC_Q1 sy-vline
WA_V_ORF5CUST_STR-EC_Q2 sy-vline
WA_V_ORF5CUST_STR-EC_DEF sy-vline
WA_V_ORF5CUST_STR-HS_Q1 sy-vline
WA_V_ORF5CUST_STR-HS_Q2 sy-vline
WA_V_ORF5CUST_STR-HS_DEF sy-vline
WA_V_ORF5CUST_STR-PRICE_Q1 sy-vline
WA_V_ORF5CUST_STR-PRICE_Q2 sy-vline
WA_V_ORF5CUST_STR-PRICE_DEF sy-vline
WA_V_ORF5CUST_STR-CURR_DEF sy-vline
WA_V_ORF5CUST_STR-NFL_Q1 sy-vline
WA_V_ORF5CUST_STR-NFL_Q2 sy-vline
WA_V_ORF5CUST_STR-NFL_DEF sy-vline
WA_V_ORF5CUST_STR-NEQ_Q1 sy-vline
WA_V_ORF5CUST_STR-NEQ_Q2 sy-vline
WA_V_ORF5CUST_STR-NEQ_DEF sy-vline
WA_V_ORF5CUST_STR-TAU_Q1 sy-vline
WA_V_ORF5CUST_STR-TAU_Q2 sy-vline
WA_V_ORF5CUST_STR-TAU_DEF_OH sy-vline
WA_V_ORF5CUST_STR-TAU_DEF_LC sy-vline
WA_V_ORF5CUST_STR-TAU_DEF_OC sy-vline
WA_V_ORF5CUST_STR-DD_DEF sy-vline
WA_V_ORF5CUST_STR-SAVE_TYPE sy-vline
WA_V_ORF5CUST_STR-CALC_TYPE2 sy-vline
WA_V_ORF5CUST_STR-ROT_EXP_TYPE sy-vline
WA_V_ORF5CUST_STR-MAD_TYPE sy-vline
WA_V_ORF5CUST_STR-BATCH_DUM1 sy-vline
WA_V_ORF5CUST_STR-BATCH_DUM2 sy-vline
WA_V_ORF5CUST_STR-BATCH_DUM3 sy-vline
WA_V_ORF5CUST_STR-SUPPL1 sy-vline
WA_V_ORF5CUST_STR-WERKS sy-vline
WA_V_ORF5CUST_STR-BWTAR sy-vline
WA_V_ORF5CUST_STR-FLAG_NUM_BATCH sy-vline
WA_V_ORF5CUST_STR-IP_MATNR_ASSIGN sy-vline
WA_V_ORF5CUST_STR-DUMMY1 sy-vline
WA_V_ORF5CUST_STR-DUMMY2 sy-vline
WA_V_ORF5CUST_STR-DUMMY3 sy-vline
WA_V_ORF5CUST_STR-DUMMY4 sy-vline
WA_V_ORF5CUST_STR-DUMMY5 sy-vline
WA_V_ORF5CUST_STR-DUMMY6 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.