ABAP Select data from SAP table V_PRODART5 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_PRODART5 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_PRODART5. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_PRODART5 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_PRODART5 TYPE STANDARD TABLE OF V_PRODART5, WA_V_PRODART5 TYPE V_PRODART5, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_PRODART5> TYPE V_PRODART5. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_PRODART5. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_PRODART5 INTO TABLE IT_V_PRODART5. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_PRODART5 * INTO TABLE @DATA(IT_V_PRODART52). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_PRODART5 INDEX 1 INTO DATA(WA_V_PRODART52). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_PRODART5 ASSIGNING <V_PRODART5>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_PRODART5>-MANDT = 1.
<V_PRODART5>-GSART = 1.
<V_PRODART5>-RANTYP = 1.
<V_PRODART5>-SANLF = 1.
<V_PRODART5>-LTX = 1.
ENDLOOP. LOOP AT IT_V_PRODART5 INTO WA_V_PRODART5. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_PRODART5-VLTX, sy-vline,
WA_V_PRODART5-DSART, sy-vline,
WA_V_PRODART5-LTXKURZ, sy-vline,
WA_V_PRODART5-SZBMETH, sy-vline,
WA_V_PRODART5-SEFFMETH, sy-vline,
WA_V_PRODART5-FACILITY_CAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_PRODART5 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_PRODART5 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_PRODART5 INTO WA_V_PRODART5. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_PRODART5_STR,
MANDT TYPE STRING,
GSART TYPE STRING,
RANTYP TYPE STRING,
SANLF TYPE STRING,
LTX TYPE STRING,
VLTX TYPE STRING,
DSART TYPE STRING,
LTXKURZ TYPE STRING,
SZBMETH TYPE STRING,
SEFFMETH TYPE STRING,
FACILITY_CAT TYPE STRING,
UTIL_FEE_CALC TYPE STRING,
CALCTYP_SEFFMETH TYPE STRING,
FIR_EFLOWS_KEEP TYPE STRING,
IDX_ON TYPE STRING,
IDX_PRORATA TYPE STRING,
CASH_FLOW_CALC TYPE STRING,
TERM_CAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_PRODART5_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_PRODART5_STR-MANDT sy-vline
WA_V_PRODART5_STR-GSART sy-vline
WA_V_PRODART5_STR-RANTYP sy-vline
WA_V_PRODART5_STR-SANLF sy-vline
WA_V_PRODART5_STR-LTX sy-vline
WA_V_PRODART5_STR-VLTX sy-vline
WA_V_PRODART5_STR-DSART sy-vline
WA_V_PRODART5_STR-LTXKURZ sy-vline
WA_V_PRODART5_STR-SZBMETH sy-vline
WA_V_PRODART5_STR-SEFFMETH sy-vline
WA_V_PRODART5_STR-FACILITY_CAT sy-vline
WA_V_PRODART5_STR-UTIL_FEE_CALC sy-vline
WA_V_PRODART5_STR-CALCTYP_SEFFMETH sy-vline
WA_V_PRODART5_STR-FIR_EFLOWS_KEEP sy-vline
WA_V_PRODART5_STR-IDX_ON sy-vline
WA_V_PRODART5_STR-IDX_PRORATA sy-vline
WA_V_PRODART5_STR-CASH_FLOW_CALC sy-vline
WA_V_PRODART5_STR-TERM_CAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.