ABAP Select data from SAP table V_RECNCNF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_RECNCNF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_RECNCNF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_RECNCNF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_RECNCNF TYPE STANDARD TABLE OF V_RECNCNF, WA_V_RECNCNF TYPE V_RECNCNF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_RECNCNF> TYPE V_RECNCNF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_RECNCNF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_RECNCNF INTO TABLE IT_V_RECNCNF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_RECNCNF * INTO TABLE @DATA(IT_V_RECNCNF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_RECNCNF INDEX 1 INTO DATA(WA_V_RECNCNF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_RECNCNF ASSIGNING <V_RECNCNF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_RECNCNF>-MANDT = 1.
<V_RECNCNF>-INTRENOBE = 1.
<V_RECNCNF>-VALIDFROM = 1.
<V_RECNCNF>-INTRENO = 1.
<V_RECNCNF>-BUKRSBE = 1.
ENDLOOP. LOOP AT IT_V_RECNCNF INTO WA_V_RECNCNF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_RECNCNF-SWENR, sy-vline,
WA_V_RECNCNF-XWETEXT, sy-vline,
WA_V_RECNCNF-VALIDTO, sy-vline,
WA_V_RECNCNF-RECNTYPE, sy-vline,
WA_V_RECNCNF-BUKRS, sy-vline,
WA_V_RECNCNF-RECNNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_RECNCNF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_RECNCNF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_RECNCNF INTO WA_V_RECNCNF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit SWENR, internal->external for field SWENR CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_V_RECNCNF-SWENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_RECNCNF-SWENR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit REDAT, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_V_RECNCNF-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_RECNCNF-VALIDTO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_RECNCNF-RECNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_RECNCNF-RECNNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit REDAT, internal->external for field RECNENDABS CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_V_RECNCNF-RECNENDABS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_RECNCNF-RECNENDABS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit SWENR, internal->external for field BENOCN CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_V_RECNCNF-BENOCN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_RECNCNF-BENOCN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit IMKEY, internal->external for field IMKEY CALL FUNCTION 'CONVERSION_EXIT_IMKEY_OUTPUT' EXPORTING input = WA_V_RECNCNF-IMKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_RECNCNF-IMKEY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_RECNCNF_STR,
MANDT TYPE STRING,
INTRENOBE TYPE STRING,
VALIDFROM TYPE STRING,
INTRENO TYPE STRING,
BUKRSBE TYPE STRING,
SWENR TYPE STRING,
XWETEXT TYPE STRING,
VALIDTO TYPE STRING,
RECNTYPE TYPE STRING,
BUKRS TYPE STRING,
RECNNR TYPE STRING,
RECNBEG TYPE STRING,
RECNENDABS TYPE STRING,
RECNTXT TYPE STRING,
BENOCN TYPE STRING,
OBJNR TYPE STRING,
IMKEY TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_RECNCNF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_RECNCNF_STR-MANDT sy-vline
WA_V_RECNCNF_STR-INTRENOBE sy-vline
WA_V_RECNCNF_STR-VALIDFROM sy-vline
WA_V_RECNCNF_STR-INTRENO sy-vline
WA_V_RECNCNF_STR-BUKRSBE sy-vline
WA_V_RECNCNF_STR-SWENR sy-vline
WA_V_RECNCNF_STR-XWETEXT sy-vline
WA_V_RECNCNF_STR-VALIDTO sy-vline
WA_V_RECNCNF_STR-RECNTYPE sy-vline
WA_V_RECNCNF_STR-BUKRS sy-vline
WA_V_RECNCNF_STR-RECNNR sy-vline
WA_V_RECNCNF_STR-RECNBEG sy-vline
WA_V_RECNCNF_STR-RECNENDABS sy-vline
WA_V_RECNCNF_STR-RECNTXT sy-vline
WA_V_RECNCNF_STR-BENOCN sy-vline
WA_V_RECNCNF_STR-OBJNR sy-vline
WA_V_RECNCNF_STR-IMKEY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.