ABAP Select data from SAP table V_SOFC_ATT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_SOFC_ATT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_SOFC_ATT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_SOFC_ATT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_SOFC_ATT TYPE STANDARD TABLE OF V_SOFC_ATT, WA_V_SOFC_ATT TYPE V_SOFC_ATT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_SOFC_ATT> TYPE V_SOFC_ATT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_SOFC_ATT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_SOFC_ATT INTO TABLE IT_V_SOFC_ATT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_SOFC_ATT * INTO TABLE @DATA(IT_V_SOFC_ATT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_SOFC_ATT INDEX 1 INTO DATA(WA_V_SOFC_ATT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_SOFC_ATT ASSIGNING <V_SOFC_ATT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_SOFC_ATT>-MANDT = 1.
<V_SOFC_ATT>-FOLTP = 1.
<V_SOFC_ATT>-FOLYR = 1.
<V_SOFC_ATT>-FOLNO = 1.
<V_SOFC_ATT>-DOCTP = 1.
ENDLOOP. LOOP AT IT_V_SOFC_ATT INTO WA_V_SOFC_ATT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_SOFC_ATT-DOCYR, sy-vline,
WA_V_SOFC_ATT-DOCNO, sy-vline,
WA_V_SOFC_ATT-FORTP, sy-vline,
WA_V_SOFC_ATT-FORYR, sy-vline,
WA_V_SOFC_ATT-FORNO, sy-vline,
WA_V_SOFC_ATT-DOCNAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_SOFC_ATT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_SOFC_ATT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_SOFC_ATT INTO WA_V_SOFC_ATT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ISOLA, internal->external for field DOCLA CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_V_SOFC_ATT-DOCLA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_SOFC_ATT-DOCLA.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_SOFC_ATT_STR,
MANDT TYPE STRING,
FOLTP TYPE STRING,
FOLYR TYPE STRING,
FOLNO TYPE STRING,
DOCTP TYPE STRING,
DOCYR TYPE STRING,
DOCNO TYPE STRING,
FORTP TYPE STRING,
FORYR TYPE STRING,
FORNO TYPE STRING,
DOCNAM TYPE STRING,
DOCDES TYPE STRING,
DOCLA TYPE STRING,
CRDAT TYPE STRING,
CRTIM TYPE STRING,
CHDAT TYPE STRING,
CHTIM TYPE STRING,
LADAT TYPE STRING,
DLDAT TYPE STRING,
OWNTP TYPE STRING,
OWNYR TYPE STRING,
OWNNO TYPE STRING,
ENCCNT TYPE STRING,
OBJSND TYPE STRING,
RECCNT TYPE STRING,
SDDAT TYPE STRING,
SDTIM TYPE STRING,
RRDCNT TYPE STRING,
SNDBC TYPE STRING,
RARCNT TYPE STRING,
RAPCNT TYPE STRING,
RATCNT TYPE STRING,
RCPCNT TYPE STRING,
RBCCNT TYPE STRING,
RRRCNT TYPE STRING,
RRPCNT TYPE STRING,
VMTYP TYPE STRING,
RESUB TYPE STRING,
RECPRI TYPE STRING,
FLAG1 TYPE STRING,
RBDAT TYPE STRING,
OBJPRI TYPE STRING,
OBJSNS TYPE STRING,
OBJCP TYPE STRING,
FIXED TYPE STRING,
FILE_EXT TYPE STRING,
LFOLTP TYPE STRING,
LFOLYR TYPE STRING,
LFOLNO TYPE STRING,
ARCHI TYPE STRING,
FOLRG TYPE STRING,
OBJLEN TYPE STRING,
OBJRD TYPE STRING,
ATTLEN TYPE STRING,
CROTP TYPE STRING,
CROYR TYPE STRING,
CRONO TYPE STRING,
CHOTP TYPE STRING,
CHOYR TYPE STRING,
CHONO TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_SOFC_ATT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_SOFC_ATT_STR-MANDT sy-vline
WA_V_SOFC_ATT_STR-FOLTP sy-vline
WA_V_SOFC_ATT_STR-FOLYR sy-vline
WA_V_SOFC_ATT_STR-FOLNO sy-vline
WA_V_SOFC_ATT_STR-DOCTP sy-vline
WA_V_SOFC_ATT_STR-DOCYR sy-vline
WA_V_SOFC_ATT_STR-DOCNO sy-vline
WA_V_SOFC_ATT_STR-FORTP sy-vline
WA_V_SOFC_ATT_STR-FORYR sy-vline
WA_V_SOFC_ATT_STR-FORNO sy-vline
WA_V_SOFC_ATT_STR-DOCNAM sy-vline
WA_V_SOFC_ATT_STR-DOCDES sy-vline
WA_V_SOFC_ATT_STR-DOCLA sy-vline
WA_V_SOFC_ATT_STR-CRDAT sy-vline
WA_V_SOFC_ATT_STR-CRTIM sy-vline
WA_V_SOFC_ATT_STR-CHDAT sy-vline
WA_V_SOFC_ATT_STR-CHTIM sy-vline
WA_V_SOFC_ATT_STR-LADAT sy-vline
WA_V_SOFC_ATT_STR-DLDAT sy-vline
WA_V_SOFC_ATT_STR-OWNTP sy-vline
WA_V_SOFC_ATT_STR-OWNYR sy-vline
WA_V_SOFC_ATT_STR-OWNNO sy-vline
WA_V_SOFC_ATT_STR-ENCCNT sy-vline
WA_V_SOFC_ATT_STR-OBJSND sy-vline
WA_V_SOFC_ATT_STR-RECCNT sy-vline
WA_V_SOFC_ATT_STR-SDDAT sy-vline
WA_V_SOFC_ATT_STR-SDTIM sy-vline
WA_V_SOFC_ATT_STR-RRDCNT sy-vline
WA_V_SOFC_ATT_STR-SNDBC sy-vline
WA_V_SOFC_ATT_STR-RARCNT sy-vline
WA_V_SOFC_ATT_STR-RAPCNT sy-vline
WA_V_SOFC_ATT_STR-RATCNT sy-vline
WA_V_SOFC_ATT_STR-RCPCNT sy-vline
WA_V_SOFC_ATT_STR-RBCCNT sy-vline
WA_V_SOFC_ATT_STR-RRRCNT sy-vline
WA_V_SOFC_ATT_STR-RRPCNT sy-vline
WA_V_SOFC_ATT_STR-VMTYP sy-vline
WA_V_SOFC_ATT_STR-RESUB sy-vline
WA_V_SOFC_ATT_STR-RECPRI sy-vline
WA_V_SOFC_ATT_STR-FLAG1 sy-vline
WA_V_SOFC_ATT_STR-RBDAT sy-vline
WA_V_SOFC_ATT_STR-OBJPRI sy-vline
WA_V_SOFC_ATT_STR-OBJSNS sy-vline
WA_V_SOFC_ATT_STR-OBJCP sy-vline
WA_V_SOFC_ATT_STR-FIXED sy-vline
WA_V_SOFC_ATT_STR-FILE_EXT sy-vline
WA_V_SOFC_ATT_STR-LFOLTP sy-vline
WA_V_SOFC_ATT_STR-LFOLYR sy-vline
WA_V_SOFC_ATT_STR-LFOLNO sy-vline
WA_V_SOFC_ATT_STR-ARCHI sy-vline
WA_V_SOFC_ATT_STR-FOLRG sy-vline
WA_V_SOFC_ATT_STR-OBJLEN sy-vline
WA_V_SOFC_ATT_STR-OBJRD sy-vline
WA_V_SOFC_ATT_STR-ATTLEN sy-vline
WA_V_SOFC_ATT_STR-CROTP sy-vline
WA_V_SOFC_ATT_STR-CROYR sy-vline
WA_V_SOFC_ATT_STR-CRONO sy-vline
WA_V_SOFC_ATT_STR-CHOTP sy-vline
WA_V_SOFC_ATT_STR-CHOYR sy-vline
WA_V_SOFC_ATT_STR-CHONO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.