ABAP Select data from SAP table V_T5D2F into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_T5D2F table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_T5D2F. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_T5D2F table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_T5D2F TYPE STANDARD TABLE OF V_T5D2F, WA_V_T5D2F TYPE V_T5D2F, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_T5D2F> TYPE V_T5D2F. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_T5D2F. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_T5D2F INTO TABLE IT_V_T5D2F. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_T5D2F * INTO TABLE @DATA(IT_V_T5D2F2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_T5D2F INDEX 1 INTO DATA(WA_V_T5D2F2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_T5D2F ASSIGNING <V_T5D2F>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_T5D2F>-MANDT = 1.
<V_T5D2F>-MOLGA = 1.
<V_T5D2F>-LGART = 1.
<V_T5D2F>-ENDDA = 1.
<V_T5D2F>-LGTXT = 1.
ENDLOOP. LOOP AT IT_V_T5D2F INTO WA_V_T5D2F. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_T5D2F-BEGDA, sy-vline,
WA_V_T5D2F-SBART, sy-vline,
WA_V_T5D2F-SRTXT, sy-vline,
WA_V_T5D2F-SORTF, sy-vline,
WA_V_T5D2F-KNVFB, sy-vline,
WA_V_T5D2F-KNAEB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_T5D2F you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_T5D2F TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_T5D2F INTO WA_V_T5D2F. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_T5D2F_STR,
MANDT TYPE STRING,
MOLGA TYPE STRING,
LGART TYPE STRING,
ENDDA TYPE STRING,
LGTXT TYPE STRING,
BEGDA TYPE STRING,
SBART TYPE STRING,
SRTXT TYPE STRING,
SORTF TYPE STRING,
KNVFB TYPE STRING,
KNAEB TYPE STRING,
KNKJL TYPE STRING,
KNLJA TYPE STRING,
KNPAN TYPE STRING,
PPSTS TYPE STRING,
TPSTS TYPE STRING,
PBSTS TYPE STRING,
TBSTS TYPE STRING,
LALST TYPE STRING,
TALST TYPE STRING,
LAKST TYPE STRING,
TAKST TYPE STRING,
LAVBZ TYPE STRING,
TAVBZ TYPE STRING,
LAVFB TYPE STRING,
TAVFB TYPE STRING,
LAAEB TYPE STRING,
TAAEB TYPE STRING,
LASOZ TYPE STRING,
TASOZ TYPE STRING,
LVBTR TYPE STRING,
TVBTR TYPE STRING,
LVLST TYPE STRING,
TVLST TYPE STRING,
LVKST TYPE STRING,
TVKST TYPE STRING,
LVVBZ TYPE STRING,
TVVBZ TYPE STRING,
LVSOZ TYPE STRING,
TVSOZ TYPE STRING,
LJLST TYPE STRING,
TJLST TYPE STRING,
LJKST TYPE STRING,
TJKST TYPE STRING,
LJVBZ TYPE STRING,
TJVBZ TYPE STRING,
LJVFB TYPE STRING,
TJVFB TYPE STRING,
LJAEB TYPE STRING,
TJAEB TYPE STRING,
LJSOZ TYPE STRING,
TJSOZ TYPE STRING,
LJBTR TYPE STRING,
TJBTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_T5D2F_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_T5D2F_STR-MANDT sy-vline
WA_V_T5D2F_STR-MOLGA sy-vline
WA_V_T5D2F_STR-LGART sy-vline
WA_V_T5D2F_STR-ENDDA sy-vline
WA_V_T5D2F_STR-LGTXT sy-vline
WA_V_T5D2F_STR-BEGDA sy-vline
WA_V_T5D2F_STR-SBART sy-vline
WA_V_T5D2F_STR-SRTXT sy-vline
WA_V_T5D2F_STR-SORTF sy-vline
WA_V_T5D2F_STR-KNVFB sy-vline
WA_V_T5D2F_STR-KNAEB sy-vline
WA_V_T5D2F_STR-KNKJL sy-vline
WA_V_T5D2F_STR-KNLJA sy-vline
WA_V_T5D2F_STR-KNPAN sy-vline
WA_V_T5D2F_STR-PPSTS sy-vline
WA_V_T5D2F_STR-TPSTS sy-vline
WA_V_T5D2F_STR-PBSTS sy-vline
WA_V_T5D2F_STR-TBSTS sy-vline
WA_V_T5D2F_STR-LALST sy-vline
WA_V_T5D2F_STR-TALST sy-vline
WA_V_T5D2F_STR-LAKST sy-vline
WA_V_T5D2F_STR-TAKST sy-vline
WA_V_T5D2F_STR-LAVBZ sy-vline
WA_V_T5D2F_STR-TAVBZ sy-vline
WA_V_T5D2F_STR-LAVFB sy-vline
WA_V_T5D2F_STR-TAVFB sy-vline
WA_V_T5D2F_STR-LAAEB sy-vline
WA_V_T5D2F_STR-TAAEB sy-vline
WA_V_T5D2F_STR-LASOZ sy-vline
WA_V_T5D2F_STR-TASOZ sy-vline
WA_V_T5D2F_STR-LVBTR sy-vline
WA_V_T5D2F_STR-TVBTR sy-vline
WA_V_T5D2F_STR-LVLST sy-vline
WA_V_T5D2F_STR-TVLST sy-vline
WA_V_T5D2F_STR-LVKST sy-vline
WA_V_T5D2F_STR-TVKST sy-vline
WA_V_T5D2F_STR-LVVBZ sy-vline
WA_V_T5D2F_STR-TVVBZ sy-vline
WA_V_T5D2F_STR-LVSOZ sy-vline
WA_V_T5D2F_STR-TVSOZ sy-vline
WA_V_T5D2F_STR-LJLST sy-vline
WA_V_T5D2F_STR-TJLST sy-vline
WA_V_T5D2F_STR-LJKST sy-vline
WA_V_T5D2F_STR-TJKST sy-vline
WA_V_T5D2F_STR-LJVBZ sy-vline
WA_V_T5D2F_STR-TJVBZ sy-vline
WA_V_T5D2F_STR-LJVFB sy-vline
WA_V_T5D2F_STR-TJVFB sy-vline
WA_V_T5D2F_STR-LJAEB sy-vline
WA_V_T5D2F_STR-TJAEB sy-vline
WA_V_T5D2F_STR-LJSOZ sy-vline
WA_V_T5D2F_STR-TJSOZ sy-vline
WA_V_T5D2F_STR-LJBTR sy-vline
WA_V_T5D2F_STR-TJBTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.