ABAP Select data from SAP table V_T5DP1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_T5DP1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_T5DP1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_T5DP1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_T5DP1 TYPE STANDARD TABLE OF V_T5DP1,
      WA_V_T5DP1 TYPE V_T5DP1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_T5DP1> TYPE V_T5DP1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_T5DP1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_T5DP1
  INTO TABLE IT_V_T5DP1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_T5DP1
*  INTO TABLE @DATA(IT_V_T5DP12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_T5DP1 INDEX 1 INTO DATA(WA_V_T5DP12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_T5DP1 ASSIGNING <V_T5DP1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_T5DP1>-MANDT = 1.
<V_T5DP1>-FLDID = 1.
<V_T5DP1>-INFTY = 1.
<V_T5DP1>-FIELD = 1.
<V_T5DP1>-FIELDART = 1.
ENDLOOP.

LOOP AT IT_V_T5DP1 INTO WA_V_T5DP1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_T5DP1-SZART, sy-vline,
WA_V_T5DP1-USART, sy-vline,
WA_V_T5DP1-FDNR, sy-vline,
WA_V_T5DP1-ENDDA, sy-vline,
WA_V_T5DP1-BEGDA, sy-vline,
WA_V_T5DP1-FTEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_T5DP1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_T5DP1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_T5DP1 INTO WA_V_T5DP1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit DTYPE, internal->external for field FLDTYP CALL FUNCTION 'CONVERSION_EXIT_DTYPE_OUTPUT' EXPORTING input = WA_V_T5DP1-FLDTYP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T5DP1-FLDTYP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_T5DP1_STR,
MANDT TYPE STRING,
FLDID TYPE STRING,
INFTY TYPE STRING,
FIELD TYPE STRING,
FIELDART TYPE STRING,
SZART TYPE STRING,
USART TYPE STRING,
FDNR TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
FTEXT TYPE STRING,
LENG TYPE STRING,
FLDTYP TYPE STRING,
PGMNA TYPE STRING,
MODNA TYPE STRING,
KONVERT TYPE STRING,
PGART TYPE STRING,
NACHBER TYPE STRING,
P4OFFSET TYPE STRING,
P4KEY TYPE STRING,
AKTIV TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_T5DP1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_T5DP1_STR-MANDT sy-vline
WA_V_T5DP1_STR-FLDID sy-vline
WA_V_T5DP1_STR-INFTY sy-vline
WA_V_T5DP1_STR-FIELD sy-vline
WA_V_T5DP1_STR-FIELDART sy-vline
WA_V_T5DP1_STR-SZART sy-vline
WA_V_T5DP1_STR-USART sy-vline
WA_V_T5DP1_STR-FDNR sy-vline
WA_V_T5DP1_STR-ENDDA sy-vline
WA_V_T5DP1_STR-BEGDA sy-vline
WA_V_T5DP1_STR-FTEXT sy-vline
WA_V_T5DP1_STR-LENG sy-vline
WA_V_T5DP1_STR-FLDTYP sy-vline
WA_V_T5DP1_STR-PGMNA sy-vline
WA_V_T5DP1_STR-MODNA sy-vline
WA_V_T5DP1_STR-KONVERT sy-vline
WA_V_T5DP1_STR-PGART sy-vline
WA_V_T5DP1_STR-NACHBER sy-vline
WA_V_T5DP1_STR-P4OFFSET sy-vline
WA_V_T5DP1_STR-P4KEY sy-vline
WA_V_T5DP1_STR-AKTIV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.