ABAP Select data from SAP table V_T5F_PP_SET_ALL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_T5F_PP_SET_ALL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_T5F_PP_SET_ALL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_T5F_PP_SET_ALL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_T5F_PP_SET_ALL TYPE STANDARD TABLE OF V_T5F_PP_SET_ALL, WA_V_T5F_PP_SET_ALL TYPE V_T5F_PP_SET_ALL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_T5F_PP_SET_ALL> TYPE V_T5F_PP_SET_ALL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_T5F_PP_SET_ALL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_T5F_PP_SET_ALL INTO TABLE IT_V_T5F_PP_SET_ALL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_T5F_PP_SET_ALL * INTO TABLE @DATA(IT_V_T5F_PP_SET_ALL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_T5F_PP_SET_ALL INDEX 1 INTO DATA(WA_V_T5F_PP_SET_ALL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_T5F_PP_SET_ALL ASSIGNING <V_T5F_PP_SET_ALL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_T5F_PP_SET_ALL>-MANDT = 1.
<V_T5F_PP_SET_ALL>-SIREN = 1.
<V_T5F_PP_SET_ALL>-NUMIC = 1.
<V_T5F_PP_SET_ALL>-DEMOI = 1.
<V_T5F_PP_SET_ALL>-CCREF = 1.
ENDLOOP. LOOP AT IT_V_T5F_PP_SET_ALL INTO WA_V_T5F_PP_SET_ALL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_T5F_PP_SET_ALL-CCORG, sy-vline,
WA_V_T5F_PP_SET_ALL-CCDEL, sy-vline,
WA_V_T5F_PP_SET_ALL-CCOPT, sy-vline,
WA_V_T5F_PP_SET_ALL-CCPOP, sy-vline,
WA_V_T5F_PP_SET_ALL-CDMOD, sy-vline,
WA_V_T5F_PP_SET_ALL-SETUP_VERSION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_T5F_PP_SET_ALL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_T5F_PP_SET_ALL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_T5F_PP_SET_ALL INTO WA_V_T5F_PP_SET_ALL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_T5F_PP_SET_ALL_STR,
MANDT TYPE STRING,
SIREN TYPE STRING,
NUMIC TYPE STRING,
DEMOI TYPE STRING,
CCREF TYPE STRING,
CCORG TYPE STRING,
CCDEL TYPE STRING,
CCOPT TYPE STRING,
CCPOP TYPE STRING,
CDMOD TYPE STRING,
SETUP_VERSION TYPE STRING,
SEQNO TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
VAKEY_T596NV TYPE STRING,
VAKEY_T596M TYPE STRING,
WERKS_SUM TYPE STRING,
BTRTL_SUM TYPE STRING,
SIRET_PY TYPE STRING,
OPSID TYPE STRING,
DSNID TYPE STRING,
ORG_TEXT TYPE STRING,
VEMOD TYPE STRING,
BIC TYPE STRING,
IBAN TYPE STRING,
UIDPM TYPE STRING,
PYMPE TYPE STRING,
TERME TYPE STRING,
CVPER TYPE STRING,
PYDATE TYPE STRING,
TYPID TYPE STRING,
CREATEDAT TYPE STRING,
RVFIR TYPE STRING,
CREATEDBY TYPE STRING,
CREATEDTIME TYPE STRING,
PYMPT TYPE STRING,
OPSSI TYPE STRING,
OPSNU TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_T5F_PP_SET_ALL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_T5F_PP_SET_ALL_STR-MANDT sy-vline
WA_V_T5F_PP_SET_ALL_STR-SIREN sy-vline
WA_V_T5F_PP_SET_ALL_STR-NUMIC sy-vline
WA_V_T5F_PP_SET_ALL_STR-DEMOI sy-vline
WA_V_T5F_PP_SET_ALL_STR-CCREF sy-vline
WA_V_T5F_PP_SET_ALL_STR-CCORG sy-vline
WA_V_T5F_PP_SET_ALL_STR-CCDEL sy-vline
WA_V_T5F_PP_SET_ALL_STR-CCOPT sy-vline
WA_V_T5F_PP_SET_ALL_STR-CCPOP sy-vline
WA_V_T5F_PP_SET_ALL_STR-CDMOD sy-vline
WA_V_T5F_PP_SET_ALL_STR-SETUP_VERSION sy-vline
WA_V_T5F_PP_SET_ALL_STR-SEQNO sy-vline
WA_V_T5F_PP_SET_ALL_STR-WERKS sy-vline
WA_V_T5F_PP_SET_ALL_STR-BTRTL sy-vline
WA_V_T5F_PP_SET_ALL_STR-VAKEY_T596NV sy-vline
WA_V_T5F_PP_SET_ALL_STR-VAKEY_T596M sy-vline
WA_V_T5F_PP_SET_ALL_STR-WERKS_SUM sy-vline
WA_V_T5F_PP_SET_ALL_STR-BTRTL_SUM sy-vline
WA_V_T5F_PP_SET_ALL_STR-SIRET_PY sy-vline
WA_V_T5F_PP_SET_ALL_STR-OPSID sy-vline
WA_V_T5F_PP_SET_ALL_STR-DSNID sy-vline
WA_V_T5F_PP_SET_ALL_STR-ORG_TEXT sy-vline
WA_V_T5F_PP_SET_ALL_STR-VEMOD sy-vline
WA_V_T5F_PP_SET_ALL_STR-BIC sy-vline
WA_V_T5F_PP_SET_ALL_STR-IBAN sy-vline
WA_V_T5F_PP_SET_ALL_STR-UIDPM sy-vline
WA_V_T5F_PP_SET_ALL_STR-PYMPE sy-vline
WA_V_T5F_PP_SET_ALL_STR-TERME sy-vline
WA_V_T5F_PP_SET_ALL_STR-CVPER sy-vline
WA_V_T5F_PP_SET_ALL_STR-PYDATE sy-vline
WA_V_T5F_PP_SET_ALL_STR-TYPID sy-vline
WA_V_T5F_PP_SET_ALL_STR-CREATEDAT sy-vline
WA_V_T5F_PP_SET_ALL_STR-RVFIR sy-vline
WA_V_T5F_PP_SET_ALL_STR-CREATEDBY sy-vline
WA_V_T5F_PP_SET_ALL_STR-CREATEDTIME sy-vline
WA_V_T5F_PP_SET_ALL_STR-PYMPT sy-vline
WA_V_T5F_PP_SET_ALL_STR-OPSSI sy-vline
WA_V_T5F_PP_SET_ALL_STR-OPSNU sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.