ABAP Select data from SAP table V_T7INPES3 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_T7INPES3 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_T7INPES3. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_T7INPES3 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_T7INPES3 TYPE STANDARD TABLE OF V_T7INPES3,
      WA_V_T7INPES3 TYPE V_T7INPES3,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_T7INPES3> TYPE V_T7INPES3.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_T7INPES3.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_T7INPES3
  INTO TABLE IT_V_T7INPES3.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_T7INPES3
*  INTO TABLE @DATA(IT_V_T7INPES32).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_T7INPES3 INDEX 1 INTO DATA(WA_V_T7INPES32).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_T7INPES3 ASSIGNING <V_T7INPES3>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_T7INPES3>-MANDT = 1.
<V_T7INPES3>-TMPID = 1.
<V_T7INPES3>-CSFLD = 1.
<V_T7INPES3>-ENDDA = 1.
<V_T7INPES3>-BEGDA = 1.
ENDLOOP.

LOOP AT IT_V_T7INPES3 INTO WA_V_T7INPES3.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_T7INPES3-FLDVT, sy-vline,
WA_V_T7INPES3-WIDTH, sy-vline,
WA_V_T7INPES3-UIPOS, sy-vline,
WA_V_T7INPES3-IVREQ, sy-vline,
WA_V_T7INPES3-IEREQ, sy-vline,
WA_V_T7INPES3-ROREQ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_T7INPES3 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_T7INPES3 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_T7INPES3 INTO WA_V_T7INPES3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_T7INPES3_STR,
MANDT TYPE STRING,
TMPID TYPE STRING,
CSFLD TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
FLDVT TYPE STRING,
WIDTH TYPE STRING,
UIPOS TYPE STRING,
IVREQ TYPE STRING,
IEREQ TYPE STRING,
ROREQ TYPE STRING,
MNDRQ TYPE STRING,
IVAPP TYPE STRING,
IEAPP TYPE STRING,
ROAPP TYPE STRING,
MNDAP TYPE STRING,
FLDOR TYPE STRING,
DFVAL TYPE STRING,
CLNME TYPE STRING,
MENME TYPE STRING,
DCLNE TYPE STRING,
DMENE TYPE STRING,
CFLBL TYPE STRING,
TLTIP TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_T7INPES3_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_T7INPES3_STR-MANDT sy-vline
WA_V_T7INPES3_STR-TMPID sy-vline
WA_V_T7INPES3_STR-CSFLD sy-vline
WA_V_T7INPES3_STR-ENDDA sy-vline
WA_V_T7INPES3_STR-BEGDA sy-vline
WA_V_T7INPES3_STR-FLDVT sy-vline
WA_V_T7INPES3_STR-WIDTH sy-vline
WA_V_T7INPES3_STR-UIPOS sy-vline
WA_V_T7INPES3_STR-IVREQ sy-vline
WA_V_T7INPES3_STR-IEREQ sy-vline
WA_V_T7INPES3_STR-ROREQ sy-vline
WA_V_T7INPES3_STR-MNDRQ sy-vline
WA_V_T7INPES3_STR-IVAPP sy-vline
WA_V_T7INPES3_STR-IEAPP sy-vline
WA_V_T7INPES3_STR-ROAPP sy-vline
WA_V_T7INPES3_STR-MNDAP sy-vline
WA_V_T7INPES3_STR-FLDOR sy-vline
WA_V_T7INPES3_STR-DFVAL sy-vline
WA_V_T7INPES3_STR-CLNME sy-vline
WA_V_T7INPES3_STR-MENME sy-vline
WA_V_T7INPES3_STR-DCLNE sy-vline
WA_V_T7INPES3_STR-DMENE sy-vline
WA_V_T7INPES3_STR-CFLBL sy-vline
WA_V_T7INPES3_STR-TLTIP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.