ABAP Select data from SAP table V_TCUSTENGIEN01 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TCUSTENGIEN01 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TCUSTENGIEN01. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_TCUSTENGIEN01 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_TCUSTENGIEN01 TYPE STANDARD TABLE OF V_TCUSTENGIEN01, WA_V_TCUSTENGIEN01 TYPE V_TCUSTENGIEN01, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_TCUSTENGIEN01> TYPE V_TCUSTENGIEN01. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_TCUSTENGIEN01. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_TCUSTENGIEN01 INTO TABLE IT_V_TCUSTENGIEN01. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_TCUSTENGIEN01 * INTO TABLE @DATA(IT_V_TCUSTENGIEN012). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_TCUSTENGIEN01 INDEX 1 INTO DATA(WA_V_TCUSTENGIEN012). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_TCUSTENGIEN01 ASSIGNING <V_TCUSTENGIEN01>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TCUSTENGIEN01>-CLIENT = 1.
<V_TCUSTENGIEN01>-OBJECT = 1.
<V_TCUSTENGIEN01>-RFC_GROUP = 1.
<V_TCUSTENGIEN01>-MAXTASKS = 1.
<V_TCUSTENGIEN01>-MAXCOUNT = 1.
ENDLOOP. LOOP AT IT_V_TCUSTENGIEN01 INTO WA_V_TCUSTENGIEN01. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_TCUSTENGIEN01-PACKAGESIZE, sy-vline,
WA_V_TCUSTENGIEN01-FOLLOW_UP_PERIOD, sy-vline,
WA_V_TCUSTENGIEN01-FOLLOW_UP_UNIT, sy-vline,
WA_V_TCUSTENGIEN01-RESIDENCE, sy-vline,
WA_V_TCUSTENGIEN01-RESIDENCE_UNIT, sy-vline,
WA_V_TCUSTENGIEN01-ARCHIVE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TCUSTENGIEN01 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TCUSTENGIEN01 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TCUSTENGIEN01 INTO WA_V_TCUSTENGIEN01. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TCUSTENGIEN01_STR,
CLIENT TYPE STRING,
OBJECT TYPE STRING,
RFC_GROUP TYPE STRING,
MAXTASKS TYPE STRING,
MAXCOUNT TYPE STRING,
PACKAGESIZE TYPE STRING,
FOLLOW_UP_PERIOD TYPE STRING,
FOLLOW_UP_UNIT TYPE STRING,
RESIDENCE TYPE STRING,
RESIDENCE_UNIT TYPE STRING,
ARCHIVE TYPE STRING,
ANALYZE TYPE STRING,
WRITE_AR TYPE STRING,
DELETE_AR TYPE STRING,
RELOAD TYPE STRING,
DELETE_WO_ARCHIV TYPE STRING,
ANALYZE_MIGRATIO TYPE STRING,
DELETE_MIGRATION TYPE STRING,
DISPLAY_ARCHIVE TYPE STRING,
BACKGROUND TYPE STRING,
UNDO_STATUS TYPE STRING,
CONSTRAINTS TYPE STRING,
MONITOR TYPE STRING,
ADAPTIVE_MULTITA TYPE STRING,
CHECK_SYSTEM TYPE STRING,
OBJECTSPEC_CUST TYPE STRING,
RESIDENCE_ASSIGN TYPE STRING,
ARCHIVING_FACTOR TYPE STRING,
LOG TYPE STRING,
DIAGNOSIS TYPE STRING,
IGNITION TYPE STRING,
RESIDENCE_MIN TYPE STRING,
ALLOW_DEL_WO_AR TYPE STRING,
SNAPSHOT TYPE STRING,
DESTRUCTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TCUSTENGIEN01_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TCUSTENGIEN01_STR-CLIENT sy-vline
WA_V_TCUSTENGIEN01_STR-OBJECT sy-vline
WA_V_TCUSTENGIEN01_STR-RFC_GROUP sy-vline
WA_V_TCUSTENGIEN01_STR-MAXTASKS sy-vline
WA_V_TCUSTENGIEN01_STR-MAXCOUNT sy-vline
WA_V_TCUSTENGIEN01_STR-PACKAGESIZE sy-vline
WA_V_TCUSTENGIEN01_STR-FOLLOW_UP_PERIOD sy-vline
WA_V_TCUSTENGIEN01_STR-FOLLOW_UP_UNIT sy-vline
WA_V_TCUSTENGIEN01_STR-RESIDENCE sy-vline
WA_V_TCUSTENGIEN01_STR-RESIDENCE_UNIT sy-vline
WA_V_TCUSTENGIEN01_STR-ARCHIVE sy-vline
WA_V_TCUSTENGIEN01_STR-ANALYZE sy-vline
WA_V_TCUSTENGIEN01_STR-WRITE_AR sy-vline
WA_V_TCUSTENGIEN01_STR-DELETE_AR sy-vline
WA_V_TCUSTENGIEN01_STR-RELOAD sy-vline
WA_V_TCUSTENGIEN01_STR-DELETE_WO_ARCHIV sy-vline
WA_V_TCUSTENGIEN01_STR-ANALYZE_MIGRATIO sy-vline
WA_V_TCUSTENGIEN01_STR-DELETE_MIGRATION sy-vline
WA_V_TCUSTENGIEN01_STR-DISPLAY_ARCHIVE sy-vline
WA_V_TCUSTENGIEN01_STR-BACKGROUND sy-vline
WA_V_TCUSTENGIEN01_STR-UNDO_STATUS sy-vline
WA_V_TCUSTENGIEN01_STR-CONSTRAINTS sy-vline
WA_V_TCUSTENGIEN01_STR-MONITOR sy-vline
WA_V_TCUSTENGIEN01_STR-ADAPTIVE_MULTITA sy-vline
WA_V_TCUSTENGIEN01_STR-CHECK_SYSTEM sy-vline
WA_V_TCUSTENGIEN01_STR-OBJECTSPEC_CUST sy-vline
WA_V_TCUSTENGIEN01_STR-RESIDENCE_ASSIGN sy-vline
WA_V_TCUSTENGIEN01_STR-ARCHIVING_FACTOR sy-vline
WA_V_TCUSTENGIEN01_STR-LOG sy-vline
WA_V_TCUSTENGIEN01_STR-DIAGNOSIS sy-vline
WA_V_TCUSTENGIEN01_STR-IGNITION sy-vline
WA_V_TCUSTENGIEN01_STR-RESIDENCE_MIN sy-vline
WA_V_TCUSTENGIEN01_STR-ALLOW_DEL_WO_AR sy-vline
WA_V_TCUSTENGIEN01_STR-SNAPSHOT sy-vline
WA_V_TCUSTENGIEN01_STR-DESTRUCTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.