ABAP Select data from SAP table V_TMTR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TMTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TMTR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_TMTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_TMTR TYPE STANDARD TABLE OF V_TMTR, WA_V_TMTR TYPE V_TMTR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_TMTR> TYPE V_TMTR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_TMTR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_TMTR INTO TABLE IT_V_TMTR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_TMTR * INTO TABLE @DATA(IT_V_TMTR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_TMTR INDEX 1 INTO DATA(WA_V_TMTR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_TMTR ASSIGNING <V_TMTR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TMTR>-MANDT = 1.
<V_TMTR>-TRANSFER_EVENT = 1.
<V_TMTR>-TRANSFER_GROUP = 1.
<V_TMTR>-RULE_NUMBER = 1.
<V_TMTR>-SOURCE_STRUCTURE = 1.
ENDLOOP. LOOP AT IT_V_TMTR INTO WA_V_TMTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_TMTR-SOURCE_FIELD, sy-vline,
WA_V_TMTR-FIXED_VALUE, sy-vline,
WA_V_TMTR-SOURCE_VAL_CLASS, sy-vline,
WA_V_TMTR-OFFSET_SOURCE, sy-vline,
WA_V_TMTR-LENGTH_SOURCE, sy-vline,
WA_V_TMTR-TARGET_STRUCTURE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TMTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TMTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TMTR INTO WA_V_TMTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit BFUID, internal->external for field BRF_FUNC_ID CALL FUNCTION 'CONVERSION_EXIT_BFUID_OUTPUT' EXPORTING input = WA_V_TMTR-BRF_FUNC_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TMTR-BRF_FUNC_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit PARVW, internal->external for field PARVW CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_V_TMTR-PARVW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TMTR-PARVW.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TMTR_STR,
MANDT TYPE STRING,
TRANSFER_EVENT TYPE STRING,
TRANSFER_GROUP TYPE STRING,
RULE_NUMBER TYPE STRING,
SOURCE_STRUCTURE TYPE STRING,
SOURCE_FIELD TYPE STRING,
FIXED_VALUE TYPE STRING,
SOURCE_VAL_CLASS TYPE STRING,
OFFSET_SOURCE TYPE STRING,
LENGTH_SOURCE TYPE STRING,
TARGET_STRUCTURE TYPE STRING,
TARGET_FIELD TYPE STRING,
TEXT_EVENT TYPE STRING,
TEXT_GROUP TYPE STRING,
COPY_REQ TYPE STRING,
COPY_MODE TYPE STRING,
REQUIREMNT_CLASS TYPE STRING,
TEXT TYPE STRING,
BRFPLUS_ENABLED TYPE STRING,
BRF_APPLICATION_ID TYPE STRING,
BRF_FUNC_ID TYPE STRING,
OFFSET_TARGET TYPE STRING,
LENGTH_TARGET TYPE STRING,
PARVW TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TMTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TMTR_STR-MANDT sy-vline
WA_V_TMTR_STR-TRANSFER_EVENT sy-vline
WA_V_TMTR_STR-TRANSFER_GROUP sy-vline
WA_V_TMTR_STR-RULE_NUMBER sy-vline
WA_V_TMTR_STR-SOURCE_STRUCTURE sy-vline
WA_V_TMTR_STR-SOURCE_FIELD sy-vline
WA_V_TMTR_STR-FIXED_VALUE sy-vline
WA_V_TMTR_STR-SOURCE_VAL_CLASS sy-vline
WA_V_TMTR_STR-OFFSET_SOURCE sy-vline
WA_V_TMTR_STR-LENGTH_SOURCE sy-vline
WA_V_TMTR_STR-TARGET_STRUCTURE sy-vline
WA_V_TMTR_STR-TARGET_FIELD sy-vline
WA_V_TMTR_STR-TEXT_EVENT sy-vline
WA_V_TMTR_STR-TEXT_GROUP sy-vline
WA_V_TMTR_STR-COPY_REQ sy-vline
WA_V_TMTR_STR-COPY_MODE sy-vline
WA_V_TMTR_STR-REQUIREMNT_CLASS sy-vline
WA_V_TMTR_STR-TEXT sy-vline
WA_V_TMTR_STR-BRFPLUS_ENABLED sy-vline
WA_V_TMTR_STR-BRF_APPLICATION_ID sy-vline
WA_V_TMTR_STR-BRF_FUNC_ID sy-vline
WA_V_TMTR_STR-OFFSET_TARGET sy-vline
WA_V_TMTR_STR-LENGTH_TARGET sy-vline
WA_V_TMTR_STR-PARVW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.