ABAP Select data from SAP table V_VEC_ASSIGNMENT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_VEC_ASSIGNMENT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_VEC_ASSIGNMENT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_VEC_ASSIGNMENT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_VEC_ASSIGNMENT TYPE STANDARD TABLE OF V_VEC_ASSIGNMENT, WA_V_VEC_ASSIGNMENT TYPE V_VEC_ASSIGNMENT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_VEC_ASSIGNMENT> TYPE V_VEC_ASSIGNMENT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_VEC_ASSIGNMENT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_VEC_ASSIGNMENT INTO TABLE IT_V_VEC_ASSIGNMENT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_VEC_ASSIGNMENT * INTO TABLE @DATA(IT_V_VEC_ASSIGNMENT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_VEC_ASSIGNMENT INDEX 1 INTO DATA(WA_V_VEC_ASSIGNMENT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_VEC_ASSIGNMENT ASSIGNING <V_VEC_ASSIGNMENT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_VEC_ASSIGNMENT>-MANDT = 1.
<V_VEC_ASSIGNMENT>-SCEN_ID = 1.
<V_VEC_ASSIGNMENT>-TASK_TYPE = 1.
<V_VEC_ASSIGNMENT>-ASSIGNMENT = 1.
<V_VEC_ASSIGNMENT>-ITEM_NO = 1.
ENDLOOP. LOOP AT IT_V_VEC_ASSIGNMENT INTO WA_V_VEC_ASSIGNMENT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_VEC_ASSIGNMENT-PC_ID, sy-vline,
WA_V_VEC_ASSIGNMENT-METHOD, sy-vline,
WA_V_VEC_ASSIGNMENT-EFFCTIVE_FROM, sy-vline,
WA_V_VEC_ASSIGNMENT-SELECTION, sy-vline,
ENDLOOP. *Add any further fields from structure WA_V_VEC_ASSIGNMENT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_VEC_ASSIGNMENT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_VEC_ASSIGNMENT INTO WA_V_VEC_ASSIGNMENT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit PERI7, internal->external for field EFFCTIVE_FROM CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_V_VEC_ASSIGNMENT-EFFCTIVE_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VEC_ASSIGNMENT-EFFCTIVE_FROM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_VEC_ASSIGNMENT_STR,
MANDT TYPE STRING,
SCEN_ID TYPE STRING,
TASK_TYPE TYPE STRING,
ASSIGNMENT TYPE STRING,
ITEM_NO TYPE STRING,
PC_ID TYPE STRING,
METHOD TYPE STRING,
EFFCTIVE_FROM TYPE STRING,
SELECTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_VEC_ASSIGNMENT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_VEC_ASSIGNMENT_STR-MANDT sy-vline
WA_V_VEC_ASSIGNMENT_STR-SCEN_ID sy-vline
WA_V_VEC_ASSIGNMENT_STR-TASK_TYPE sy-vline
WA_V_VEC_ASSIGNMENT_STR-ASSIGNMENT sy-vline
WA_V_VEC_ASSIGNMENT_STR-ITEM_NO sy-vline
WA_V_VEC_ASSIGNMENT_STR-PC_ID sy-vline
WA_V_VEC_ASSIGNMENT_STR-METHOD sy-vline
WA_V_VEC_ASSIGNMENT_STR-EFFCTIVE_FROM sy-vline
WA_V_VEC_ASSIGNMENT_STR-SELECTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.