ABAP Select data from SAP table VC2OD_S_DEP_GENERAL_DATA_SP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP VC2OD_S_DEP_GENERAL_DATA_SP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VC2OD_S_DEP_GENERAL_DATA_SP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the VC2OD_S_DEP_GENERAL_DATA_SP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_VC2OD_S_DEP_GENERAL_DATA_SP TYPE STANDARD TABLE OF VC2OD_S_DEP_GENERAL_DATA_SP, WA_VC2OD_S_DEP_GENERAL_DATA_SP TYPE VC2OD_S_DEP_GENERAL_DATA_SP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <VC2OD_S_DEP_GENERAL_DATA_SP> TYPE VC2OD_S_DEP_GENERAL_DATA_SP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_VC2OD_S_DEP_GENERAL_DATA_SP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM VC2OD_S_DEP_GENERAL_DATA_SP INTO TABLE IT_VC2OD_S_DEP_GENERAL_DATA_SP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM VC2OD_S_DEP_GENERAL_DATA_SP * INTO TABLE @DATA(IT_VC2OD_S_DEP_GENERAL_DATA_SP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_VC2OD_S_DEP_GENERAL_DATA_SP INDEX 1 INTO DATA(WA_VC2OD_S_DEP_GENERAL_DATA_SP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_VC2OD_S_DEP_GENERAL_DATA_SP ASSIGNING <VC2OD_S_DEP_GENERAL_DATA_SP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<VC2OD_S_DEP_GENERAL_DATA_SP>-DEPENDENCY_NO = 1.
<VC2OD_S_DEP_GENERAL_DATA_SP>-KEY_DATE = 1.
<VC2OD_S_DEP_GENERAL_DATA_SP>-CHANGE_NUMBER = 1.
<VC2OD_S_DEP_GENERAL_DATA_SP>-LEAD_OBJ_TYPE = 1.
<VC2OD_S_DEP_GENERAL_DATA_SP>-ASSIGNMENT_NO = 1.
ENDLOOP. LOOP AT IT_VC2OD_S_DEP_GENERAL_DATA_SP INTO WA_VC2OD_S_DEP_GENERAL_DATA_SP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_VC2OD_S_DEP_GENERAL_DATA_SP-DEPENDENCY_NO_INTERNAL, sy-vline,
WA_VC2OD_S_DEP_GENERAL_DATA_SP-DEP_DESC, sy-vline,
WA_VC2OD_S_DEP_GENERAL_DATA_SP-DEP_TYPE, sy-vline,
WA_VC2OD_S_DEP_GENERAL_DATA_SP-DEP_TYPE_DESC, sy-vline,
WA_VC2OD_S_DEP_GENERAL_DATA_SP-DEP_GROUP, sy-vline,
WA_VC2OD_S_DEP_GENERAL_DATA_SP-DEP_GROUP_DESC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VC2OD_S_DEP_GENERAL_DATA_SP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VC2OD_S_DEP_GENERAL_DATA_SP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VC2OD_S_DEP_GENERAL_DATA_SP INTO WA_VC2OD_S_DEP_GENERAL_DATA_SP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field CHANGE_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VC2OD_S_DEP_GENERAL_DATA_SP-CHANGE_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VC2OD_S_DEP_GENERAL_DATA_SP-CHANGE_NUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VC2OD_S_DEP_GENERAL_DATA_SP_STR,
DEPENDENCY_NO TYPE STRING,
KEY_DATE TYPE STRING,
CHANGE_NUMBER TYPE STRING,
LEAD_OBJ_TYPE TYPE STRING,
ASSIGNMENT_NO TYPE STRING,
DEPENDENCY_NO_INTERNAL TYPE STRING,
DEP_DESC TYPE STRING,
DEP_TYPE TYPE STRING,
DEP_TYPE_DESC TYPE STRING,
DEP_GROUP TYPE STRING,
DEP_GROUP_DESC TYPE STRING,
DEP_STATUS TYPE STRING,
DEP_STATUS_DESC TYPE STRING,
MAINT_AUTH TYPE STRING,
MAINT_AUTH_DESC TYPE STRING,
CREATE_DATE TYPE STRING,
CREATE_USER TYPE STRING,
CREATE_USER_NAME TYPE STRING,
CHANGE_DATE TYPE STRING,
CHANGE_USER TYPE STRING,
CHANGE_USER_NAME TYPE STRING,
SCE_FORMAT_IND TYPE STRING,
IS_LOCKED_AND_CHANGEABLE TYPE STRING,
IS_GLOBAL_DEPENDENCY TYPE STRING,
LONG_TEXT_IND TYPE STRING,
REACTIVATE_IND TYPE STRING,
VALID_FROM_DATE_ECN TYPE STRING,
UI_MODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-DEPENDENCY_NO sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-KEY_DATE sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-CHANGE_NUMBER sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-LEAD_OBJ_TYPE sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-ASSIGNMENT_NO sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-DEPENDENCY_NO_INTERNAL sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-DEP_DESC sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-DEP_TYPE sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-DEP_TYPE_DESC sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-DEP_GROUP sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-DEP_GROUP_DESC sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-DEP_STATUS sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-DEP_STATUS_DESC sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-MAINT_AUTH sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-MAINT_AUTH_DESC sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-CREATE_DATE sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-CREATE_USER sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-CREATE_USER_NAME sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-CHANGE_DATE sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-CHANGE_USER sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-CHANGE_USER_NAME sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-SCE_FORMAT_IND sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-IS_LOCKED_AND_CHANGEABLE sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-IS_GLOBAL_DEPENDENCY sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-LONG_TEXT_IND sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-REACTIVATE_IND sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-VALID_FROM_DATE_ECN sy-vline
WA_VC2OD_S_DEP_GENERAL_DATA_SP_STR-UI_MODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.