ABAP Select data from SAP table VCH_SIMULATION into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP VCH_SIMULATION table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VCH_SIMULATION. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the VCH_SIMULATION table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_VCH_SIMULATION TYPE STANDARD TABLE OF VCH_SIMULATION, WA_VCH_SIMULATION TYPE VCH_SIMULATION, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <VCH_SIMULATION> TYPE VCH_SIMULATION. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_VCH_SIMULATION. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM VCH_SIMULATION INTO TABLE IT_VCH_SIMULATION. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM VCH_SIMULATION * INTO TABLE @DATA(IT_VCH_SIMULATION2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_VCH_SIMULATION INDEX 1 INTO DATA(WA_VCH_SIMULATION2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_VCH_SIMULATION ASSIGNING <VCH_SIMULATION>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<VCH_SIMULATION>-MANDT = 1.
<VCH_SIMULATION>-ID = 1.
<VCH_SIMULATION>-NAME = 1.
<VCH_SIMULATION>-CREATED_ON = 1.
<VCH_SIMULATION>-CHANGED_ON = 1.
ENDLOOP. LOOP AT IT_VCH_SIMULATION INTO WA_VCH_SIMULATION. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_VCH_SIMULATION-CREATED_BY, sy-vline,
WA_VCH_SIMULATION-CHANGED_BY, sy-vline,
WA_VCH_SIMULATION-CREATED_ON_TIME, sy-vline,
WA_VCH_SIMULATION-CHANGED_ON_TIME, sy-vline,
WA_VCH_SIMULATION-SIMULATION_EXTERNAL_ID, sy-vline,
WA_VCH_SIMULATION-APPLICATION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VCH_SIMULATION you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VCH_SIMULATION TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VCH_SIMULATION INTO WA_VCH_SIMULATION. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VCH_SIMULATION-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCH_SIMULATION-UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field PRODUCT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_VCH_SIMULATION-PRODUCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCH_SIMULATION-PRODUCT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VCH_SIMULATION_STR,
MANDT TYPE STRING,
ID TYPE STRING,
NAME TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_ON TYPE STRING,
CREATED_BY TYPE STRING,
CHANGED_BY TYPE STRING,
CREATED_ON_TIME TYPE STRING,
CHANGED_ON_TIME TYPE STRING,
SIMULATION_EXTERNAL_ID TYPE STRING,
APPLICATION TYPE STRING,
SIMULATION_DATE TYPE STRING,
QUANTITY TYPE STRING,
UOM TYPE STRING,
PRODUCT TYPE STRING,
PLANT TYPE STRING,
CUOBJ TYPE STRING,
STATUS TYPE STRING,
CONFIGURATIONPROFILECOUNTER TYPE STRING,
SIMULATION_CONTEXT TYPE STRING,
TEMPLATE_OBJ_CUOBJ TYPE STRING,
TEMPLATE_OBJ_TYPE TYPE STRING,
TEMPLATE_OBJ_ID TYPE STRING,
TEMPLATE_OBJ_ITEM_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_VCH_SIMULATION_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VCH_SIMULATION_STR-MANDT sy-vline
WA_VCH_SIMULATION_STR-ID sy-vline
WA_VCH_SIMULATION_STR-NAME sy-vline
WA_VCH_SIMULATION_STR-CREATED_ON sy-vline
WA_VCH_SIMULATION_STR-CHANGED_ON sy-vline
WA_VCH_SIMULATION_STR-CREATED_BY sy-vline
WA_VCH_SIMULATION_STR-CHANGED_BY sy-vline
WA_VCH_SIMULATION_STR-CREATED_ON_TIME sy-vline
WA_VCH_SIMULATION_STR-CHANGED_ON_TIME sy-vline
WA_VCH_SIMULATION_STR-SIMULATION_EXTERNAL_ID sy-vline
WA_VCH_SIMULATION_STR-APPLICATION sy-vline
WA_VCH_SIMULATION_STR-SIMULATION_DATE sy-vline
WA_VCH_SIMULATION_STR-QUANTITY sy-vline
WA_VCH_SIMULATION_STR-UOM sy-vline
WA_VCH_SIMULATION_STR-PRODUCT sy-vline
WA_VCH_SIMULATION_STR-PLANT sy-vline
WA_VCH_SIMULATION_STR-CUOBJ sy-vline
WA_VCH_SIMULATION_STR-STATUS sy-vline
WA_VCH_SIMULATION_STR-CONFIGURATIONPROFILECOUNTER sy-vline
WA_VCH_SIMULATION_STR-SIMULATION_CONTEXT sy-vline
WA_VCH_SIMULATION_STR-TEMPLATE_OBJ_CUOBJ sy-vline
WA_VCH_SIMULATION_STR-TEMPLATE_OBJ_TYPE sy-vline
WA_VCH_SIMULATION_STR-TEMPLATE_OBJ_ID sy-vline
WA_VCH_SIMULATION_STR-TEMPLATE_OBJ_ITEM_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.