ABAP Select data from SAP table VCIT006D into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP VCIT006D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VCIT006D. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the VCIT006D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_VCIT006D TYPE STANDARD TABLE OF VCIT006D, WA_VCIT006D TYPE VCIT006D, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <VCIT006D> TYPE VCIT006D. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_VCIT006D. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM VCIT006D INTO TABLE IT_VCIT006D. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM VCIT006D * INTO TABLE @DATA(IT_VCIT006D2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_VCIT006D INDEX 1 INTO DATA(WA_VCIT006D2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_VCIT006D ASSIGNING <VCIT006D>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<VCIT006D>-MANDT = 1.
<VCIT006D>-DIMID = 1.
<VCIT006D>-LENG = 1.
<VCIT006D>-MASS = 1.
<VCIT006D>-TIMEX = 1.
ENDLOOP. LOOP AT IT_VCIT006D INTO WA_VCIT006D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_VCIT006D-ECURR, sy-vline,
WA_VCIT006D-TEMP, sy-vline,
WA_VCIT006D-MOLQU, sy-vline,
WA_VCIT006D-LIGHT, sy-vline,
WA_VCIT006D-MSSIE, sy-vline,
WA_VCIT006D-TEMP_DEP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VCIT006D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VCIT006D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VCIT006D INTO WA_VCIT006D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CUNIT, internal->external for field MSSIE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VCIT006D-MSSIE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCIT006D-MSSIE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VCIT006D_STR,
MANDT TYPE STRING,
DIMID TYPE STRING,
LENG TYPE STRING,
MASS TYPE STRING,
TIMEX TYPE STRING,
ECURR TYPE STRING,
TEMP TYPE STRING,
MOLQU TYPE STRING,
LIGHT TYPE STRING,
MSSIE TYPE STRING,
TEMP_DEP TYPE STRING,
PRESS_DEP TYPE STRING,END OF T_EKKO_STR. DATA: WA_VCIT006D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VCIT006D_STR-MANDT sy-vline
WA_VCIT006D_STR-DIMID sy-vline
WA_VCIT006D_STR-LENG sy-vline
WA_VCIT006D_STR-MASS sy-vline
WA_VCIT006D_STR-TIMEX sy-vline
WA_VCIT006D_STR-ECURR sy-vline
WA_VCIT006D_STR-TEMP sy-vline
WA_VCIT006D_STR-MOLQU sy-vline
WA_VCIT006D_STR-LIGHT sy-vline
WA_VCIT006D_STR-MSSIE sy-vline
WA_VCIT006D_STR-TEMP_DEP sy-vline
WA_VCIT006D_STR-PRESS_DEP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.