ABAP Select data from SAP table VIBDPR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VIBDPR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VIBDPR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VIBDPR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VIBDPR TYPE STANDARD TABLE OF VIBDPR,
      WA_VIBDPR TYPE VIBDPR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VIBDPR> TYPE VIBDPR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VIBDPR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VIBDPR
  INTO TABLE IT_VIBDPR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VIBDPR
*  INTO TABLE @DATA(IT_VIBDPR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VIBDPR INDEX 1 INTO DATA(WA_VIBDPR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VIBDPR ASSIGNING <VIBDPR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VIBDPR>-MANDT = 1.
<VIBDPR>-INTRENO = 1.
<VIBDPR>-BUKRS = 1.
<VIBDPR>-SWENR = 1.
<VIBDPR>-SGRNR = 1.
ENDLOOP.

LOOP AT IT_VIBDPR INTO WA_VIBDPR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VIBDPR-OBJNR, sy-vline,
WA_VIBDPR-IMKEY, sy-vline,
WA_VIBDPR-CREATIONTYPE, sy-vline,
WA_VIBDPR-RERF, sy-vline,
WA_VIBDPR-DERF, sy-vline,
WA_VIBDPR-TERF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VIBDPR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VIBDPR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VIBDPR INTO WA_VIBDPR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SWENR, internal->external for field SWENR CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_VIBDPR-SWENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIBDPR-SWENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SGRNR, internal->external for field SGRNR CALL FUNCTION 'CONVERSION_EXIT_SGRNR_OUTPUT' EXPORTING input = WA_VIBDPR-SGRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIBDPR-SGRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit IMKEY, internal->external for field IMKEY CALL FUNCTION 'CONVERSION_EXIT_IMKEY_OUTPUT' EXPORTING input = WA_VIBDPR-IMKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIBDPR-IMKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_VIBDPR-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIBDPR-VALIDTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VIBDPR-LEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIBDPR-LEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field USGFUNCTION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIBDPR-USGFUNCTION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIBDPR-USGFUNCTION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VIBDPR_STR,
MANDT TYPE STRING,
INTRENO TYPE STRING,
BUKRS TYPE STRING,
SWENR TYPE STRING,
SGRNR TYPE STRING,
OBJNR TYPE STRING,
IMKEY TYPE STRING,
CREATIONTYPE TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
RESPONSIBLE TYPE STRING,
USEREXCLUSIVE TYPE STRING,
AUTHGRP TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
XGRTXT TYPE STRING,
RGRNART TYPE STRING,
BDMQMB1 TYPE STRING,
BDMQMB2 TYPE STRING,
BDNRWERT TYPE STRING,
BDNWERT TYPE STRING,
DBDNWERT TYPE STRING,
RBEPLAN TYPE STRING,
DBEPLAN TYPE STRING,
XNUTZGRU TYPE STRING,
NZGRZ TYPE STRING,
NZGFZ TYPE STRING,
NZBMZ TYPE STRING,
NTGRZ TYPE STRING,
NTGFZ TYPE STRING,
NTBMZ TYPE STRING,
RNBPLAN TYPE STRING,
SGRART TYPE STRING,
SGRQAL TYPE STRING,
SGRFRM TYPE STRING,
SGRGZS TYPE STRING,
DWIRTUB TYPE STRING,
DVERKAUF TYPE STRING,
SUNUTZA TYPE STRING,
JUNUTZA TYPE STRING,
DVRKPLAN TYPE STRING,
XGEMARK TYPE STRING,
NFLURNR TYPE STRING,
XFLURST TYPE STRING,
BRFLURST TYPE STRING,
JERBBAU TYPE STRING,
GEMEINDE TYPE STRING,
ZULBAUH TYPE STRING,
LEINS TYPE STRING,
WAERS TYPE STRING,
USGFUNCTION TYPE STRING,
PLANNO TYPE STRING,
LOCATIONCH TYPE STRING,
ESTATEDESCR TYPE STRING,
GEMEINDECH TYPE STRING,
SECCO TYPE STRING,
BUPLA TYPE STRING,
VPT TYPE STRING,
CURRENCY TYPE STRING,END OF T_EKKO_STR. DATA: WA_VIBDPR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VIBDPR_STR-MANDT sy-vline
WA_VIBDPR_STR-INTRENO sy-vline
WA_VIBDPR_STR-BUKRS sy-vline
WA_VIBDPR_STR-SWENR sy-vline
WA_VIBDPR_STR-SGRNR sy-vline
WA_VIBDPR_STR-OBJNR sy-vline
WA_VIBDPR_STR-IMKEY sy-vline
WA_VIBDPR_STR-CREATIONTYPE sy-vline
WA_VIBDPR_STR-RERF sy-vline
WA_VIBDPR_STR-DERF sy-vline
WA_VIBDPR_STR-TERF sy-vline
WA_VIBDPR_STR-REHER sy-vline
WA_VIBDPR_STR-RBEAR sy-vline
WA_VIBDPR_STR-DBEAR sy-vline
WA_VIBDPR_STR-TBEAR sy-vline
WA_VIBDPR_STR-RBHER sy-vline
WA_VIBDPR_STR-RESPONSIBLE sy-vline
WA_VIBDPR_STR-USEREXCLUSIVE sy-vline
WA_VIBDPR_STR-AUTHGRP sy-vline
WA_VIBDPR_STR-VALIDFROM sy-vline
WA_VIBDPR_STR-VALIDTO sy-vline
WA_VIBDPR_STR-XGRTXT sy-vline
WA_VIBDPR_STR-RGRNART sy-vline
WA_VIBDPR_STR-BDMQMB1 sy-vline
WA_VIBDPR_STR-BDMQMB2 sy-vline
WA_VIBDPR_STR-BDNRWERT sy-vline
WA_VIBDPR_STR-BDNWERT sy-vline
WA_VIBDPR_STR-DBDNWERT sy-vline
WA_VIBDPR_STR-RBEPLAN sy-vline
WA_VIBDPR_STR-DBEPLAN sy-vline
WA_VIBDPR_STR-XNUTZGRU sy-vline
WA_VIBDPR_STR-NZGRZ sy-vline
WA_VIBDPR_STR-NZGFZ sy-vline
WA_VIBDPR_STR-NZBMZ sy-vline
WA_VIBDPR_STR-NTGRZ sy-vline
WA_VIBDPR_STR-NTGFZ sy-vline
WA_VIBDPR_STR-NTBMZ sy-vline
WA_VIBDPR_STR-RNBPLAN sy-vline
WA_VIBDPR_STR-SGRART sy-vline
WA_VIBDPR_STR-SGRQAL sy-vline
WA_VIBDPR_STR-SGRFRM sy-vline
WA_VIBDPR_STR-SGRGZS sy-vline
WA_VIBDPR_STR-DWIRTUB sy-vline
WA_VIBDPR_STR-DVERKAUF sy-vline
WA_VIBDPR_STR-SUNUTZA sy-vline
WA_VIBDPR_STR-JUNUTZA sy-vline
WA_VIBDPR_STR-DVRKPLAN sy-vline
WA_VIBDPR_STR-XGEMARK sy-vline
WA_VIBDPR_STR-NFLURNR sy-vline
WA_VIBDPR_STR-XFLURST sy-vline
WA_VIBDPR_STR-BRFLURST sy-vline
WA_VIBDPR_STR-JERBBAU sy-vline
WA_VIBDPR_STR-GEMEINDE sy-vline
WA_VIBDPR_STR-ZULBAUH sy-vline
WA_VIBDPR_STR-LEINS sy-vline
WA_VIBDPR_STR-WAERS sy-vline
WA_VIBDPR_STR-USGFUNCTION sy-vline
WA_VIBDPR_STR-PLANNO sy-vline
WA_VIBDPR_STR-LOCATIONCH sy-vline
WA_VIBDPR_STR-ESTATEDESCR sy-vline
WA_VIBDPR_STR-GEMEINDECH sy-vline
WA_VIBDPR_STR-SECCO sy-vline
WA_VIBDPR_STR-BUPLA sy-vline
WA_VIBDPR_STR-VPT sy-vline
WA_VIBDPR_STR-CURRENCY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.