ABAP Select data from SAP table VIQMFEL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP VIQMFEL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VIQMFEL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the VIQMFEL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_VIQMFEL TYPE STANDARD TABLE OF VIQMFEL, WA_VIQMFEL TYPE VIQMFEL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <VIQMFEL> TYPE VIQMFEL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_VIQMFEL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM VIQMFEL INTO TABLE IT_VIQMFEL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM VIQMFEL * INTO TABLE @DATA(IT_VIQMFEL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_VIQMFEL INDEX 1 INTO DATA(WA_VIQMFEL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_VIQMFEL ASSIGNING <VIQMFEL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<VIQMFEL>-MANDT = 1.
<VIQMFEL>-QMNUM = 1.
<VIQMFEL>-FENUM = 1.
<VIQMFEL>-ERNAM = 1.
<VIQMFEL>-ERDAT = 1.
ENDLOOP. LOOP AT IT_VIQMFEL INTO WA_VIQMFEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_VIQMFEL-AENAM, sy-vline,
WA_VIQMFEL-AEDAT, sy-vline,
WA_VIQMFEL-FETXT, sy-vline,
WA_VIQMFEL-FEGRP, sy-vline,
WA_VIQMFEL-FECOD, sy-vline,
WA_VIQMFEL-FEVER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VIQMFEL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VIQMFEL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VIQMFEL INTO WA_VIQMFEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-QMNUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field FEVER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-FEVER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-FEVER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OTVER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-OTVER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-OTVER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field BAUTL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_VIQMFEL-BAUTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-BAUTL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNITFLBEW CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VIQMFEL-UNITFLBEW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-UNITFLBEW.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-AUFNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_VIQMFEL-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field REVLV CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_VIQMFEL-REVLV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-REVLV.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field KUNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-KUNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-KUNUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LIFNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-LIFNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-LIFNUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-VBELN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ADRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-ADRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-ADRNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-EQUNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MAUEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VIQMFEL-MAUEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-MAUEH.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field BTPLN CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_VIQMFEL-BTPLN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-BTPLN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field BEQUI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-BEQUI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-BEQUI.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_VIQMFEL-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-TPLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-KOSTL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSP, internal->external for field PROID CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_VIQMFEL-PROID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-PROID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ANLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-ANLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-ANLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ANLUN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-ANLUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-ANLUN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DAUFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-DAUFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-DAUFN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ADRNR_ILOA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-ADRNR_ILOA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-ADRNR_ILOA.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-KDAUF.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GERNR, internal->external for field SERIALNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_VIQMFEL-SERIALNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-SERIALNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EQUNR_ITEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIQMFEL-EQUNR_ITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-EQUNR_ITEM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field TPLNR_ITEM CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_VIQMFEL-TPLNR_ITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIQMFEL-TPLNR_ITEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VIQMFEL_STR,
MANDT TYPE STRING,
QMNUM TYPE STRING,
FENUM TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
AENAM TYPE STRING,
AEDAT TYPE STRING,
FETXT TYPE STRING,
FEGRP TYPE STRING,
FECOD TYPE STRING,
FEVER TYPE STRING,
OTGRP TYPE STRING,
OTEIL TYPE STRING,
OTVER TYPE STRING,
BAUTL TYPE STRING,
ERZEIT TYPE STRING,
AEZEIT TYPE STRING,
KZORG TYPE STRING,
WDFEH TYPE STRING,
ANZFEHLER TYPE STRING,
KZSYSFE TYPE STRING,
PROBENR TYPE STRING,
MERKNR TYPE STRING,
UNITFLBEW TYPE STRING,
FEHLBEW TYPE STRING,
INDTX TYPE STRING,
KZMLA TYPE STRING,
FEKAT TYPE STRING,
OTKAT TYPE STRING,
EBORT TYPE STRING,
QMART TYPE STRING,
QMTXT TYPE STRING,
ARTPR TYPE STRING,
MZEIT TYPE STRING,
QMDAT TYPE STRING,
QMNAM TYPE STRING,
STRMN TYPE STRING,
STRUR TYPE STRING,
LTRMN TYPE STRING,
LTRUR TYPE STRING,
WAERS TYPE STRING,
AUFNR TYPE STRING,
MATNR TYPE STRING,
REVLV TYPE STRING,
KUNUM TYPE STRING,
FEKNZ TYPE STRING,
MAKNZ TYPE STRING,
OBJNR TYPE STRING,
QMDAB TYPE STRING,
QMZAB TYPE STRING,
RBNR TYPE STRING,
RBNRI TYPE STRING,
HERKZ TYPE STRING,
BEZDT TYPE STRING,
BEZUR TYPE STRING,
LIFNUM TYPE STRING,
VBELN TYPE STRING,
BSTNK TYPE STRING,
BSTDK TYPE STRING,
SPART TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
ADRNR TYPE STRING,
QMKAT TYPE STRING,
QMGRP TYPE STRING,
QMCOD TYPE STRING,
ARBPL TYPE STRING,
ARBPLWERK TYPE STRING,
FEART TYPE STRING,
PNLKN TYPE STRING,
IWERK TYPE STRING,
ILOAN TYPE STRING,
ILOAI TYPE STRING,
EQUNR TYPE STRING,
MSAUS TYPE STRING,
AUSVN TYPE STRING,
AUSBS TYPE STRING,
AUZTV TYPE STRING,
AUZTB TYPE STRING,
AUSZT TYPE STRING,
MAUEH TYPE STRING,
BTPLN TYPE STRING,
BEQUI TYPE STRING,
AUSWK TYPE STRING,
VERFV TYPE STRING,
VERFN TYPE STRING,
VERFM TYPE STRING,
ANLZV TYPE STRING,
ANLZN TYPE STRING,
ANLZE TYPE STRING,
INSPK TYPE STRING,
DATAN TYPE STRING,
INGRP TYPE STRING,
ILART TYPE STRING,
TPLNR TYPE STRING,
ABCKZ TYPE STRING,
EQFNR TYPE STRING,
SWERK TYPE STRING,
STORT TYPE STRING,
MSGRP TYPE STRING,
BEBER TYPE STRING,
CR_OBJTY TYPE STRING,
PPSID TYPE STRING,
GSBER TYPE STRING,
KOKRS TYPE STRING,
KOSTL TYPE STRING,
PROID TYPE STRING,
BUKRS TYPE STRING,
ANLNR TYPE STRING,
ANLUN TYPE STRING,
DAUFN TYPE STRING,
ADRNR_ILOA TYPE STRING,
PRIOK TYPE STRING,
OWNER TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
KZLOESCH TYPE STRING,
VKBUR TYPE STRING,
VKGRP TYPE STRING,
SERIALNR TYPE STRING,
DEVICEID TYPE STRING,
POSNR TYPE STRING,
FEQKLAS TYPE STRING,
PHASE TYPE STRING,
UII TYPE STRING,
EQUNR_ITEM TYPE STRING,
TPLNR_ITEM TYPE STRING,END OF T_EKKO_STR. DATA: WA_VIQMFEL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VIQMFEL_STR-MANDT sy-vline
WA_VIQMFEL_STR-QMNUM sy-vline
WA_VIQMFEL_STR-FENUM sy-vline
WA_VIQMFEL_STR-ERNAM sy-vline
WA_VIQMFEL_STR-ERDAT sy-vline
WA_VIQMFEL_STR-AENAM sy-vline
WA_VIQMFEL_STR-AEDAT sy-vline
WA_VIQMFEL_STR-FETXT sy-vline
WA_VIQMFEL_STR-FEGRP sy-vline
WA_VIQMFEL_STR-FECOD sy-vline
WA_VIQMFEL_STR-FEVER sy-vline
WA_VIQMFEL_STR-OTGRP sy-vline
WA_VIQMFEL_STR-OTEIL sy-vline
WA_VIQMFEL_STR-OTVER sy-vline
WA_VIQMFEL_STR-BAUTL sy-vline
WA_VIQMFEL_STR-ERZEIT sy-vline
WA_VIQMFEL_STR-AEZEIT sy-vline
WA_VIQMFEL_STR-KZORG sy-vline
WA_VIQMFEL_STR-WDFEH sy-vline
WA_VIQMFEL_STR-ANZFEHLER sy-vline
WA_VIQMFEL_STR-KZSYSFE sy-vline
WA_VIQMFEL_STR-PROBENR sy-vline
WA_VIQMFEL_STR-MERKNR sy-vline
WA_VIQMFEL_STR-UNITFLBEW sy-vline
WA_VIQMFEL_STR-FEHLBEW sy-vline
WA_VIQMFEL_STR-INDTX sy-vline
WA_VIQMFEL_STR-KZMLA sy-vline
WA_VIQMFEL_STR-FEKAT sy-vline
WA_VIQMFEL_STR-OTKAT sy-vline
WA_VIQMFEL_STR-EBORT sy-vline
WA_VIQMFEL_STR-QMART sy-vline
WA_VIQMFEL_STR-QMTXT sy-vline
WA_VIQMFEL_STR-ARTPR sy-vline
WA_VIQMFEL_STR-MZEIT sy-vline
WA_VIQMFEL_STR-QMDAT sy-vline
WA_VIQMFEL_STR-QMNAM sy-vline
WA_VIQMFEL_STR-STRMN sy-vline
WA_VIQMFEL_STR-STRUR sy-vline
WA_VIQMFEL_STR-LTRMN sy-vline
WA_VIQMFEL_STR-LTRUR sy-vline
WA_VIQMFEL_STR-WAERS sy-vline
WA_VIQMFEL_STR-AUFNR sy-vline
WA_VIQMFEL_STR-MATNR sy-vline
WA_VIQMFEL_STR-REVLV sy-vline
WA_VIQMFEL_STR-KUNUM sy-vline
WA_VIQMFEL_STR-FEKNZ sy-vline
WA_VIQMFEL_STR-MAKNZ sy-vline
WA_VIQMFEL_STR-OBJNR sy-vline
WA_VIQMFEL_STR-QMDAB sy-vline
WA_VIQMFEL_STR-QMZAB sy-vline
WA_VIQMFEL_STR-RBNR sy-vline
WA_VIQMFEL_STR-RBNRI sy-vline
WA_VIQMFEL_STR-HERKZ sy-vline
WA_VIQMFEL_STR-BEZDT sy-vline
WA_VIQMFEL_STR-BEZUR sy-vline
WA_VIQMFEL_STR-LIFNUM sy-vline
WA_VIQMFEL_STR-VBELN sy-vline
WA_VIQMFEL_STR-BSTNK sy-vline
WA_VIQMFEL_STR-BSTDK sy-vline
WA_VIQMFEL_STR-SPART sy-vline
WA_VIQMFEL_STR-VKORG sy-vline
WA_VIQMFEL_STR-VTWEG sy-vline
WA_VIQMFEL_STR-ADRNR sy-vline
WA_VIQMFEL_STR-QMKAT sy-vline
WA_VIQMFEL_STR-QMGRP sy-vline
WA_VIQMFEL_STR-QMCOD sy-vline
WA_VIQMFEL_STR-ARBPL sy-vline
WA_VIQMFEL_STR-ARBPLWERK sy-vline
WA_VIQMFEL_STR-FEART sy-vline
WA_VIQMFEL_STR-PNLKN sy-vline
WA_VIQMFEL_STR-IWERK sy-vline
WA_VIQMFEL_STR-ILOAN sy-vline
WA_VIQMFEL_STR-ILOAI sy-vline
WA_VIQMFEL_STR-EQUNR sy-vline
WA_VIQMFEL_STR-MSAUS sy-vline
WA_VIQMFEL_STR-AUSVN sy-vline
WA_VIQMFEL_STR-AUSBS sy-vline
WA_VIQMFEL_STR-AUZTV sy-vline
WA_VIQMFEL_STR-AUZTB sy-vline
WA_VIQMFEL_STR-AUSZT sy-vline
WA_VIQMFEL_STR-MAUEH sy-vline
WA_VIQMFEL_STR-BTPLN sy-vline
WA_VIQMFEL_STR-BEQUI sy-vline
WA_VIQMFEL_STR-AUSWK sy-vline
WA_VIQMFEL_STR-VERFV sy-vline
WA_VIQMFEL_STR-VERFN sy-vline
WA_VIQMFEL_STR-VERFM sy-vline
WA_VIQMFEL_STR-ANLZV sy-vline
WA_VIQMFEL_STR-ANLZN sy-vline
WA_VIQMFEL_STR-ANLZE sy-vline
WA_VIQMFEL_STR-INSPK sy-vline
WA_VIQMFEL_STR-DATAN sy-vline
WA_VIQMFEL_STR-INGRP sy-vline
WA_VIQMFEL_STR-ILART sy-vline
WA_VIQMFEL_STR-TPLNR sy-vline
WA_VIQMFEL_STR-ABCKZ sy-vline
WA_VIQMFEL_STR-EQFNR sy-vline
WA_VIQMFEL_STR-SWERK sy-vline
WA_VIQMFEL_STR-STORT sy-vline
WA_VIQMFEL_STR-MSGRP sy-vline
WA_VIQMFEL_STR-BEBER sy-vline
WA_VIQMFEL_STR-CR_OBJTY sy-vline
WA_VIQMFEL_STR-PPSID sy-vline
WA_VIQMFEL_STR-GSBER sy-vline
WA_VIQMFEL_STR-KOKRS sy-vline
WA_VIQMFEL_STR-KOSTL sy-vline
WA_VIQMFEL_STR-PROID sy-vline
WA_VIQMFEL_STR-BUKRS sy-vline
WA_VIQMFEL_STR-ANLNR sy-vline
WA_VIQMFEL_STR-ANLUN sy-vline
WA_VIQMFEL_STR-DAUFN sy-vline
WA_VIQMFEL_STR-ADRNR_ILOA sy-vline
WA_VIQMFEL_STR-PRIOK sy-vline
WA_VIQMFEL_STR-OWNER sy-vline
WA_VIQMFEL_STR-KDAUF sy-vline
WA_VIQMFEL_STR-KDPOS sy-vline
WA_VIQMFEL_STR-KZLOESCH sy-vline
WA_VIQMFEL_STR-VKBUR sy-vline
WA_VIQMFEL_STR-VKGRP sy-vline
WA_VIQMFEL_STR-SERIALNR sy-vline
WA_VIQMFEL_STR-DEVICEID sy-vline
WA_VIQMFEL_STR-POSNR sy-vline
WA_VIQMFEL_STR-FEQKLAS sy-vline
WA_VIQMFEL_STR-PHASE sy-vline
WA_VIQMFEL_STR-UII sy-vline
WA_VIQMFEL_STR-EQUNR_ITEM sy-vline
WA_VIQMFEL_STR-TPLNR_ITEM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.