ABAP Select data from SAP table VISCS_MSU_SU_TAB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VISCS_MSU_SU_TAB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VISCS_MSU_SU_TAB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VISCS_MSU_SU_TAB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VISCS_MSU_SU_TAB TYPE STANDARD TABLE OF VISCS_MSU_SU_TAB,
      WA_VISCS_MSU_SU_TAB TYPE VISCS_MSU_SU_TAB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VISCS_MSU_SU_TAB> TYPE VISCS_MSU_SU_TAB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VISCS_MSU_SU_TAB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VISCS_MSU_SU_TAB
  INTO TABLE IT_VISCS_MSU_SU_TAB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VISCS_MSU_SU_TAB
*  INTO TABLE @DATA(IT_VISCS_MSU_SU_TAB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VISCS_MSU_SU_TAB INDEX 1 INTO DATA(WA_VISCS_MSU_SU_TAB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VISCS_MSU_SU_TAB ASSIGNING <VISCS_MSU_SU_TAB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VISCS_MSU_SU_TAB>-SETTL_GUID = 1.
<VISCS_MSU_SU_TAB>-SCS_SU_MEAS_GUID = 1.
<VISCS_MSU_SU_TAB>-APPORTVALUE = 1.
<VISCS_MSU_SU_TAB>-APPORTVALUEOPT = 1.
<VISCS_MSU_SU_TAB>-APPORTVALUEMSU = 1.
ENDLOOP.

LOOP AT IT_VISCS_MSU_SU_TAB INTO WA_VISCS_MSU_SU_TAB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VISCS_MSU_SU_TAB-APPORTVALMSUOPT, sy-vline,
WA_VISCS_MSU_SU_TAB-PURPOSE, sy-vline,
WA_VISCS_MSU_SU_TAB-MEAS, sy-vline,
WA_VISCS_MSU_SU_TAB-SU_MEAS, sy-vline,
WA_VISCS_MSU_SU_TAB-CURRENCY, sy-vline,
WA_VISCS_MSU_SU_TAB-NETAMOUNT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VISCS_MSU_SU_TAB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VISCS_MSU_SU_TAB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VISCS_MSU_SU_TAB INTO WA_VISCS_MSU_SU_TAB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field MEAS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VISCS_MSU_SU_TAB-MEAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VISCS_MSU_SU_TAB-MEAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SU_MEAS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VISCS_MSU_SU_TAB-SU_MEAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VISCS_MSU_SU_TAB-SU_MEAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VISCS_MSU_SU_TAB_STR,
SETTL_GUID TYPE STRING,
SCS_SU_MEAS_GUID TYPE STRING,
APPORTVALUE TYPE STRING,
APPORTVALUEOPT TYPE STRING,
APPORTVALUEMSU TYPE STRING,
APPORTVALMSUOPT TYPE STRING,
PURPOSE TYPE STRING,
MEAS TYPE STRING,
SU_MEAS TYPE STRING,
CURRENCY TYPE STRING,
NETAMOUNT TYPE STRING,
NONDEDTAXAMT TYPE STRING,
DEDTAXAMOUNT TYPE STRING,
OPTRATE TYPE STRING,
IS_ONLY4MEAS TYPE STRING,
IS_ONLY4OPTRATE TYPE STRING,
METERFROMRO TYPE STRING,END OF T_EKKO_STR. DATA: WA_VISCS_MSU_SU_TAB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VISCS_MSU_SU_TAB_STR-SETTL_GUID sy-vline
WA_VISCS_MSU_SU_TAB_STR-SCS_SU_MEAS_GUID sy-vline
WA_VISCS_MSU_SU_TAB_STR-APPORTVALUE sy-vline
WA_VISCS_MSU_SU_TAB_STR-APPORTVALUEOPT sy-vline
WA_VISCS_MSU_SU_TAB_STR-APPORTVALUEMSU sy-vline
WA_VISCS_MSU_SU_TAB_STR-APPORTVALMSUOPT sy-vline
WA_VISCS_MSU_SU_TAB_STR-PURPOSE sy-vline
WA_VISCS_MSU_SU_TAB_STR-MEAS sy-vline
WA_VISCS_MSU_SU_TAB_STR-SU_MEAS sy-vline
WA_VISCS_MSU_SU_TAB_STR-CURRENCY sy-vline
WA_VISCS_MSU_SU_TAB_STR-NETAMOUNT sy-vline
WA_VISCS_MSU_SU_TAB_STR-NONDEDTAXAMT sy-vline
WA_VISCS_MSU_SU_TAB_STR-DEDTAXAMOUNT sy-vline
WA_VISCS_MSU_SU_TAB_STR-OPTRATE sy-vline
WA_VISCS_MSU_SU_TAB_STR-IS_ONLY4MEAS sy-vline
WA_VISCS_MSU_SU_TAB_STR-IS_ONLY4OPTRATE sy-vline
WA_VISCS_MSU_SU_TAB_STR-METERFROMRO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.