ABAP Select data from SAP table VIXCPTSIPT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VIXCPTSIPT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VIXCPTSIPT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VIXCPTSIPT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VIXCPTSIPT TYPE STANDARD TABLE OF VIXCPTSIPT,
      WA_VIXCPTSIPT TYPE VIXCPTSIPT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VIXCPTSIPT> TYPE VIXCPTSIPT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VIXCPTSIPT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VIXCPTSIPT
  INTO TABLE IT_VIXCPTSIPT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VIXCPTSIPT
*  INTO TABLE @DATA(IT_VIXCPTSIPT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VIXCPTSIPT INDEX 1 INTO DATA(WA_VIXCPTSIPT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VIXCPTSIPT ASSIGNING <VIXCPTSIPT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VIXCPTSIPT>-MANDT = 1.
<VIXCPTSIPT>-INVGUID = 1.
<VIXCPTSIPT>-BUKRS = 1.
<VIXCPTSIPT>-INVNO = 1.
<VIXCPTSIPT>-FISC_YEAR = 1.
ENDLOOP.

LOOP AT IT_VIXCPTSIPT INTO WA_VIXCPTSIPT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VIXCPTSIPT-NRRANGENR, sy-vline,
WA_VIXCPTSIPT-TOYEAR, sy-vline,
WA_VIXCPTSIPT-LEAD_DOCTYPE, sy-vline,
WA_VIXCPTSIPT-SERIES, sy-vline,
WA_VIXCPTSIPT-INV_DATE, sy-vline,
WA_VIXCPTSIPT-SY_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VIXCPTSIPT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VIXCPTSIPT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VIXCPTSIPT INTO WA_VIXCPTSIPT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field FISC_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_VIXCPTSIPT-FISC_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIXCPTSIPT-FISC_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field TOYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_VIXCPTSIPT-TOYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIXCPTSIPT-TOYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VIXCPTSIPT_STR,
MANDT TYPE STRING,
INVGUID TYPE STRING,
BUKRS TYPE STRING,
INVNO TYPE STRING,
FISC_YEAR TYPE STRING,
NRRANGENR TYPE STRING,
TOYEAR TYPE STRING,
LEAD_DOCTYPE TYPE STRING,
SERIES TYPE STRING,
INV_DATE TYPE STRING,
SY_DATE TYPE STRING,
INV_NO TYPE STRING,
GROSS_TOTAL TYPE STRING,
WT_TOTAL TYPE STRING,
PREVPRINT_CHAR TYPE STRING,
PRINT_CHAR TYPE STRING,
CERT_ID TYPE STRING,
KEY_VERS TYPE STRING,
CREAUSER TYPE STRING,
CREADATE TYPE STRING,
CREATIME TYPE STRING,
CHANUSER TYPE STRING,
CHANDATE TYPE STRING,
CHANTIME TYPE STRING,
SIGNATURE TYPE STRING,END OF T_EKKO_STR. DATA: WA_VIXCPTSIPT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VIXCPTSIPT_STR-MANDT sy-vline
WA_VIXCPTSIPT_STR-INVGUID sy-vline
WA_VIXCPTSIPT_STR-BUKRS sy-vline
WA_VIXCPTSIPT_STR-INVNO sy-vline
WA_VIXCPTSIPT_STR-FISC_YEAR sy-vline
WA_VIXCPTSIPT_STR-NRRANGENR sy-vline
WA_VIXCPTSIPT_STR-TOYEAR sy-vline
WA_VIXCPTSIPT_STR-LEAD_DOCTYPE sy-vline
WA_VIXCPTSIPT_STR-SERIES sy-vline
WA_VIXCPTSIPT_STR-INV_DATE sy-vline
WA_VIXCPTSIPT_STR-SY_DATE sy-vline
WA_VIXCPTSIPT_STR-INV_NO sy-vline
WA_VIXCPTSIPT_STR-GROSS_TOTAL sy-vline
WA_VIXCPTSIPT_STR-WT_TOTAL sy-vline
WA_VIXCPTSIPT_STR-PREVPRINT_CHAR sy-vline
WA_VIXCPTSIPT_STR-PRINT_CHAR sy-vline
WA_VIXCPTSIPT_STR-CERT_ID sy-vline
WA_VIXCPTSIPT_STR-KEY_VERS sy-vline
WA_VIXCPTSIPT_STR-CREAUSER sy-vline
WA_VIXCPTSIPT_STR-CREADATE sy-vline
WA_VIXCPTSIPT_STR-CREATIME sy-vline
WA_VIXCPTSIPT_STR-CHANUSER sy-vline
WA_VIXCPTSIPT_STR-CHANDATE sy-vline
WA_VIXCPTSIPT_STR-CHANTIME sy-vline
WA_VIXCPTSIPT_STR-SIGNATURE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.