ABAP Select data from SAP table VSAFAB_CN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VSAFAB_CN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VSAFAB_CN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VSAFAB_CN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VSAFAB_CN TYPE STANDARD TABLE OF VSAFAB_CN,
      WA_VSAFAB_CN TYPE VSAFAB_CN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VSAFAB_CN> TYPE VSAFAB_CN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VSAFAB_CN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VSAFAB_CN
  INTO TABLE IT_VSAFAB_CN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VSAFAB_CN
*  INTO TABLE @DATA(IT_VSAFAB_CN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VSAFAB_CN INDEX 1 INTO DATA(WA_VSAFAB_CN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VSAFAB_CN ASSIGNING <VSAFAB_CN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VSAFAB_CN>-MANDT = 1.
<VSAFAB_CN>-VSNMR = 1.
<VSAFAB_CN>-AUFPL_VOR = 1.
<VSAFAB_CN>-APLZL_VOR = 1.
<VSAFAB_CN>-AUFPL_NCH = 1.
ENDLOOP.

LOOP AT IT_VSAFAB_CN INTO WA_VSAFAB_CN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VSAFAB_CN-APLZL_NCH, sy-vline,
WA_VSAFAB_CN-AOBAR, sy-vline,
WA_VSAFAB_CN-MIMAX, sy-vline,
WA_VSAFAB_CN-OBJNR, sy-vline,
WA_VSAFAB_CN-ZEINH, sy-vline,
WA_VSAFAB_CN-DAUER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VSAFAB_CN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VSAFAB_CN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VSAFAB_CN INTO WA_VSAFAB_CN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AOBAR, internal->external for field AOBAR CALL FUNCTION 'CONVERSION_EXIT_AOBAR_OUTPUT' EXPORTING input = WA_VSAFAB_CN-AOBAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSAFAB_CN-AOBAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VSAFAB_CN-ZEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSAFAB_CN-ZEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VSAFAB_CN-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSAFAB_CN-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VSAFAB_CN_STR,
MANDT TYPE STRING,
VSNMR TYPE STRING,
AUFPL_VOR TYPE STRING,
APLZL_VOR TYPE STRING,
AUFPL_NCH TYPE STRING,
APLZL_NCH TYPE STRING,
AOBAR TYPE STRING,
MIMAX TYPE STRING,
OBJNR TYPE STRING,
ZEINH TYPE STRING,
DAUER TYPE STRING,
DAUKZ TYPE STRING,
VORNC TYPE STRING,
NCVOR TYPE STRING,
LOEKZ TYPE STRING,
KALID TYPE STRING,
PRZNT TYPE STRING,
PROVG TYPE STRING,
ARBID TYPE STRING,
WERKS TYPE STRING,
FSABD TYPE STRING,
FSABZ TYPE STRING,
SSABD TYPE STRING,
SSABZ TYPE STRING,
FEABD TYPE STRING,
FEABZ TYPE STRING,
SEABD TYPE STRING,
SEABZ TYPE STRING,
DAUTM TYPE STRING,
AUCRE TYPE STRING,
DAUERMAX TYPE STRING,
AENNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_VSAFAB_CN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VSAFAB_CN_STR-MANDT sy-vline
WA_VSAFAB_CN_STR-VSNMR sy-vline
WA_VSAFAB_CN_STR-AUFPL_VOR sy-vline
WA_VSAFAB_CN_STR-APLZL_VOR sy-vline
WA_VSAFAB_CN_STR-AUFPL_NCH sy-vline
WA_VSAFAB_CN_STR-APLZL_NCH sy-vline
WA_VSAFAB_CN_STR-AOBAR sy-vline
WA_VSAFAB_CN_STR-MIMAX sy-vline
WA_VSAFAB_CN_STR-OBJNR sy-vline
WA_VSAFAB_CN_STR-ZEINH sy-vline
WA_VSAFAB_CN_STR-DAUER sy-vline
WA_VSAFAB_CN_STR-DAUKZ sy-vline
WA_VSAFAB_CN_STR-VORNC sy-vline
WA_VSAFAB_CN_STR-NCVOR sy-vline
WA_VSAFAB_CN_STR-LOEKZ sy-vline
WA_VSAFAB_CN_STR-KALID sy-vline
WA_VSAFAB_CN_STR-PRZNT sy-vline
WA_VSAFAB_CN_STR-PROVG sy-vline
WA_VSAFAB_CN_STR-ARBID sy-vline
WA_VSAFAB_CN_STR-WERKS sy-vline
WA_VSAFAB_CN_STR-FSABD sy-vline
WA_VSAFAB_CN_STR-FSABZ sy-vline
WA_VSAFAB_CN_STR-SSABD sy-vline
WA_VSAFAB_CN_STR-SSABZ sy-vline
WA_VSAFAB_CN_STR-FEABD sy-vline
WA_VSAFAB_CN_STR-FEABZ sy-vline
WA_VSAFAB_CN_STR-SEABD sy-vline
WA_VSAFAB_CN_STR-SEABZ sy-vline
WA_VSAFAB_CN_STR-DAUTM sy-vline
WA_VSAFAB_CN_STR-AUCRE sy-vline
WA_VSAFAB_CN_STR-DAUERMAX sy-vline
WA_VSAFAB_CN_STR-AENNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.