ABAP Select data from SAP table VSFPLT_CN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VSFPLT_CN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VSFPLT_CN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VSFPLT_CN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VSFPLT_CN TYPE STANDARD TABLE OF VSFPLT_CN,
      WA_VSFPLT_CN TYPE VSFPLT_CN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VSFPLT_CN> TYPE VSFPLT_CN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VSFPLT_CN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VSFPLT_CN
  INTO TABLE IT_VSFPLT_CN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VSFPLT_CN
*  INTO TABLE @DATA(IT_VSFPLT_CN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VSFPLT_CN INDEX 1 INTO DATA(WA_VSFPLT_CN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VSFPLT_CN ASSIGNING <VSFPLT_CN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VSFPLT_CN>-MANDT = 1.
<VSFPLT_CN>-VSNMR = 1.
<VSFPLT_CN>-FPLNR = 1.
<VSFPLT_CN>-FPLTR = 1.
<VSFPLT_CN>-FPTTP = 1.
ENDLOOP.

LOOP AT IT_VSFPLT_CN INTO WA_VSFPLT_CN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VSFPLT_CN-TETXT, sy-vline,
WA_VSFPLT_CN-FKDAT, sy-vline,
WA_VSFPLT_CN-FPFIX, sy-vline,
WA_VSFPLT_CN-FAREG, sy-vline,
WA_VSFPLT_CN-FPROZ, sy-vline,
WA_VSFPLT_CN-WAERS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VSFPLT_CN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VSFPLT_CN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VSFPLT_CN INTO WA_VSFPLT_CN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit EXCRT, internal->external for field KURFP CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_VSFPLT_CN-KURFP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSFPLT_CN-KURFP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNRG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VSFPLT_CN-KUNRG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSFPLT_CN-KUNRG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURRF CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_VSFPLT_CN-KURRF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSFPLT_CN-KURRF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CCACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VSFPLT_CN-CCACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSFPLT_CN-CCACT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VSFPLT_CN_STR,
MANDT TYPE STRING,
VSNMR TYPE STRING,
FPLNR TYPE STRING,
FPLTR TYPE STRING,
FPTTP TYPE STRING,
TETXT TYPE STRING,
FKDAT TYPE STRING,
FPFIX TYPE STRING,
FAREG TYPE STRING,
FPROZ TYPE STRING,
WAERS TYPE STRING,
KURFP TYPE STRING,
FAKWR TYPE STRING,
FAKSP TYPE STRING,
FKARV TYPE STRING,
FKSAF TYPE STRING,
PERIO TYPE STRING,
FPLAE TYPE STRING,
MLSTN TYPE STRING,
MLBEZ TYPE STRING,
ZTERM TYPE STRING,
KUNRG TYPE STRING,
TAXK1 TYPE STRING,
TAXK2 TYPE STRING,
TAXK3 TYPE STRING,
TAXK4 TYPE STRING,
TAXK5 TYPE STRING,
TAXK6 TYPE STRING,
TAXK7 TYPE STRING,
TAXK8 TYPE STRING,
TAXK9 TYPE STRING,
VALTG TYPE STRING,
VALDT TYPE STRING,
NFDAT TYPE STRING,
TEMAN TYPE STRING,
FAKCA TYPE STRING,
AFDAT TYPE STRING,
NETWR TYPE STRING,
NETPR TYPE STRING,
WAVWR TYPE STRING,
KZWI1 TYPE STRING,
KZWI2 TYPE STRING,
KZWI3 TYPE STRING,
KZWI4 TYPE STRING,
KZWI5 TYPE STRING,
KZWI6 TYPE STRING,
CMPRE TYPE STRING,
SKFBP TYPE STRING,
BONBA TYPE STRING,
PRSOK TYPE STRING,
TYPZM TYPE STRING,
CMPRE_FLT TYPE STRING,
UELNR TYPE STRING,
UELTR TYPE STRING,
KURRF TYPE STRING,
CCACT TYPE STRING,
KORTE TYPE STRING,
OFKDAT TYPE STRING,
AD04FAREG TYPE STRING,END OF T_EKKO_STR. DATA: WA_VSFPLT_CN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VSFPLT_CN_STR-MANDT sy-vline
WA_VSFPLT_CN_STR-VSNMR sy-vline
WA_VSFPLT_CN_STR-FPLNR sy-vline
WA_VSFPLT_CN_STR-FPLTR sy-vline
WA_VSFPLT_CN_STR-FPTTP sy-vline
WA_VSFPLT_CN_STR-TETXT sy-vline
WA_VSFPLT_CN_STR-FKDAT sy-vline
WA_VSFPLT_CN_STR-FPFIX sy-vline
WA_VSFPLT_CN_STR-FAREG sy-vline
WA_VSFPLT_CN_STR-FPROZ sy-vline
WA_VSFPLT_CN_STR-WAERS sy-vline
WA_VSFPLT_CN_STR-KURFP sy-vline
WA_VSFPLT_CN_STR-FAKWR sy-vline
WA_VSFPLT_CN_STR-FAKSP sy-vline
WA_VSFPLT_CN_STR-FKARV sy-vline
WA_VSFPLT_CN_STR-FKSAF sy-vline
WA_VSFPLT_CN_STR-PERIO sy-vline
WA_VSFPLT_CN_STR-FPLAE sy-vline
WA_VSFPLT_CN_STR-MLSTN sy-vline
WA_VSFPLT_CN_STR-MLBEZ sy-vline
WA_VSFPLT_CN_STR-ZTERM sy-vline
WA_VSFPLT_CN_STR-KUNRG sy-vline
WA_VSFPLT_CN_STR-TAXK1 sy-vline
WA_VSFPLT_CN_STR-TAXK2 sy-vline
WA_VSFPLT_CN_STR-TAXK3 sy-vline
WA_VSFPLT_CN_STR-TAXK4 sy-vline
WA_VSFPLT_CN_STR-TAXK5 sy-vline
WA_VSFPLT_CN_STR-TAXK6 sy-vline
WA_VSFPLT_CN_STR-TAXK7 sy-vline
WA_VSFPLT_CN_STR-TAXK8 sy-vline
WA_VSFPLT_CN_STR-TAXK9 sy-vline
WA_VSFPLT_CN_STR-VALTG sy-vline
WA_VSFPLT_CN_STR-VALDT sy-vline
WA_VSFPLT_CN_STR-NFDAT sy-vline
WA_VSFPLT_CN_STR-TEMAN sy-vline
WA_VSFPLT_CN_STR-FAKCA sy-vline
WA_VSFPLT_CN_STR-AFDAT sy-vline
WA_VSFPLT_CN_STR-NETWR sy-vline
WA_VSFPLT_CN_STR-NETPR sy-vline
WA_VSFPLT_CN_STR-WAVWR sy-vline
WA_VSFPLT_CN_STR-KZWI1 sy-vline
WA_VSFPLT_CN_STR-KZWI2 sy-vline
WA_VSFPLT_CN_STR-KZWI3 sy-vline
WA_VSFPLT_CN_STR-KZWI4 sy-vline
WA_VSFPLT_CN_STR-KZWI5 sy-vline
WA_VSFPLT_CN_STR-KZWI6 sy-vline
WA_VSFPLT_CN_STR-CMPRE sy-vline
WA_VSFPLT_CN_STR-SKFBP sy-vline
WA_VSFPLT_CN_STR-BONBA sy-vline
WA_VSFPLT_CN_STR-PRSOK sy-vline
WA_VSFPLT_CN_STR-TYPZM sy-vline
WA_VSFPLT_CN_STR-CMPRE_FLT sy-vline
WA_VSFPLT_CN_STR-UELNR sy-vline
WA_VSFPLT_CN_STR-UELTR sy-vline
WA_VSFPLT_CN_STR-KURRF sy-vline
WA_VSFPLT_CN_STR-CCACT sy-vline
WA_VSFPLT_CN_STR-KORTE sy-vline
WA_VSFPLT_CN_STR-OFKDAT sy-vline
WA_VSFPLT_CN_STR-AD04FAREG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.