ABAP Select data from SAP table VTG_FC_REP1 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP VTG_FC_REP1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VTG_FC_REP1. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the VTG_FC_REP1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_VTG_FC_REP1 TYPE STANDARD TABLE OF VTG_FC_REP1, WA_VTG_FC_REP1 TYPE VTG_FC_REP1, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <VTG_FC_REP1> TYPE VTG_FC_REP1. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_VTG_FC_REP1. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM VTG_FC_REP1 INTO TABLE IT_VTG_FC_REP1. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM VTG_FC_REP1 * INTO TABLE @DATA(IT_VTG_FC_REP12). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_VTG_FC_REP1 INDEX 1 INTO DATA(WA_VTG_FC_REP12). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_VTG_FC_REP1 ASSIGNING <VTG_FC_REP1>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<VTG_FC_REP1>-MANDT = 1.
<VTG_FC_REP1>-BUKRS = 1.
<VTG_FC_REP1>-RFHA = 1.
<VTG_FC_REP1>-CRUSER = 1.
<VTG_FC_REP1>-DCRDAT = 1.
ENDLOOP. LOOP AT IT_VTG_FC_REP1 INTO WA_VTG_FC_REP1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_VTG_FC_REP1-TCRTIM, sy-vline,
WA_VTG_FC_REP1-UPUSER, sy-vline,
WA_VTG_FC_REP1-DUPDAT, sy-vline,
WA_VTG_FC_REP1-TUPTIM, sy-vline,
WA_VTG_FC_REP1-RANTYP, sy-vline,
WA_VTG_FC_REP1-SANLF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VTG_FC_REP1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VTG_FC_REP1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VTG_FC_REP1 INTO WA_VTG_FC_REP1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RFHA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VTG_FC_REP1-RFHA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VTG_FC_REP1-RFHA.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field KONTRH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VTG_FC_REP1-KONTRH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VTG_FC_REP1-KONTRH.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RGARANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VTG_FC_REP1-RGARANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VTG_FC_REP1-RGARANT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VTG_FC_REP1_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
RFHA TYPE STRING,
CRUSER TYPE STRING,
DCRDAT TYPE STRING,
TCRTIM TYPE STRING,
UPUSER TYPE STRING,
DUPDAT TYPE STRING,
TUPTIM TYPE STRING,
RANTYP TYPE STRING,
SANLF TYPE STRING,
SFGTYP TYPE STRING,
SGSART TYPE STRING,
SFHAART TYPE STRING,
KONTRH TYPE STRING,
SAKTIV TYPE STRING,
RFHAZUL TYPE STRING,
RPORTB TYPE STRING,
WGSCHFT TYPE STRING,
DBLFZ TYPE STRING,
DELFZ TYPE STRING,
SKALID TYPE STRING,
SKALID2 TYPE STRING,
OBJNR TYPE STRING,
RLDEPO TYPE STRING,
ZUONR TYPE STRING,
ZUOND TYPE STRING,
REFER TYPE STRING,
MERKM TYPE STRING,
SFRGZUST TYPE STRING,
RGARANT TYPE STRING,
RREFKONT TYPE STRING,
RREFKONT2 TYPE STRING,
ABWTYP TYPE STRING,
SFUNKTV TYPE STRING,
SFUNKTL TYPE STRING,
SFGZUSTT TYPE STRING,
RDEALER TYPE STRING,
DVTRAB TYPE STRING,
TVTRAB TYPE STRING,
GSPPART TYPE STRING,
NORDEXT TYPE STRING,
AMNT_DELTA TYPE STRING,
AMNT_LIMIT TYPE STRING,
AMNT_USED TYPE STRING,
AMNT_FREE TYPE STRING,
AMNT_OVER TYPE STRING,
DSTICH TYPE STRING,
XBUKRS TYPE STRING,
XGSART TYPE STRING,
XFHAART TYPE STRING,
XABWTYP TYPE STRING,
SKUENDT TYPE STRING,
SKUENDM TYPE STRING,
XAKTIV TYPE STRING,
XFRGZUST TYPE STRING,
XKONTRH TYPE STRING,
XGARANT TYPE STRING,
XFGTYP TYPE STRING,
XPGTYP TYPE STRING,
XFGZUSTT TYPE STRING,
XFUNKTV TYPE STRING,
XFUNKTL TYPE STRING,
XPORTB TYPE STRING,
XLDEPO TYPE STRING,
XREFKONT TYPE STRING,
XREFKONT2 TYPE STRING,
ICON_ALARM TYPE STRING,END OF T_EKKO_STR. DATA: WA_VTG_FC_REP1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VTG_FC_REP1_STR-MANDT sy-vline
WA_VTG_FC_REP1_STR-BUKRS sy-vline
WA_VTG_FC_REP1_STR-RFHA sy-vline
WA_VTG_FC_REP1_STR-CRUSER sy-vline
WA_VTG_FC_REP1_STR-DCRDAT sy-vline
WA_VTG_FC_REP1_STR-TCRTIM sy-vline
WA_VTG_FC_REP1_STR-UPUSER sy-vline
WA_VTG_FC_REP1_STR-DUPDAT sy-vline
WA_VTG_FC_REP1_STR-TUPTIM sy-vline
WA_VTG_FC_REP1_STR-RANTYP sy-vline
WA_VTG_FC_REP1_STR-SANLF sy-vline
WA_VTG_FC_REP1_STR-SFGTYP sy-vline
WA_VTG_FC_REP1_STR-SGSART sy-vline
WA_VTG_FC_REP1_STR-SFHAART sy-vline
WA_VTG_FC_REP1_STR-KONTRH sy-vline
WA_VTG_FC_REP1_STR-SAKTIV sy-vline
WA_VTG_FC_REP1_STR-RFHAZUL sy-vline
WA_VTG_FC_REP1_STR-RPORTB sy-vline
WA_VTG_FC_REP1_STR-WGSCHFT sy-vline
WA_VTG_FC_REP1_STR-DBLFZ sy-vline
WA_VTG_FC_REP1_STR-DELFZ sy-vline
WA_VTG_FC_REP1_STR-SKALID sy-vline
WA_VTG_FC_REP1_STR-SKALID2 sy-vline
WA_VTG_FC_REP1_STR-OBJNR sy-vline
WA_VTG_FC_REP1_STR-RLDEPO sy-vline
WA_VTG_FC_REP1_STR-ZUONR sy-vline
WA_VTG_FC_REP1_STR-ZUOND sy-vline
WA_VTG_FC_REP1_STR-REFER sy-vline
WA_VTG_FC_REP1_STR-MERKM sy-vline
WA_VTG_FC_REP1_STR-SFRGZUST sy-vline
WA_VTG_FC_REP1_STR-RGARANT sy-vline
WA_VTG_FC_REP1_STR-RREFKONT sy-vline
WA_VTG_FC_REP1_STR-RREFKONT2 sy-vline
WA_VTG_FC_REP1_STR-ABWTYP sy-vline
WA_VTG_FC_REP1_STR-SFUNKTV sy-vline
WA_VTG_FC_REP1_STR-SFUNKTL sy-vline
WA_VTG_FC_REP1_STR-SFGZUSTT sy-vline
WA_VTG_FC_REP1_STR-RDEALER sy-vline
WA_VTG_FC_REP1_STR-DVTRAB sy-vline
WA_VTG_FC_REP1_STR-TVTRAB sy-vline
WA_VTG_FC_REP1_STR-GSPPART sy-vline
WA_VTG_FC_REP1_STR-NORDEXT sy-vline
WA_VTG_FC_REP1_STR-AMNT_DELTA sy-vline
WA_VTG_FC_REP1_STR-AMNT_LIMIT sy-vline
WA_VTG_FC_REP1_STR-AMNT_USED sy-vline
WA_VTG_FC_REP1_STR-AMNT_FREE sy-vline
WA_VTG_FC_REP1_STR-AMNT_OVER sy-vline
WA_VTG_FC_REP1_STR-DSTICH sy-vline
WA_VTG_FC_REP1_STR-XBUKRS sy-vline
WA_VTG_FC_REP1_STR-XGSART sy-vline
WA_VTG_FC_REP1_STR-XFHAART sy-vline
WA_VTG_FC_REP1_STR-XABWTYP sy-vline
WA_VTG_FC_REP1_STR-SKUENDT sy-vline
WA_VTG_FC_REP1_STR-SKUENDM sy-vline
WA_VTG_FC_REP1_STR-XAKTIV sy-vline
WA_VTG_FC_REP1_STR-XFRGZUST sy-vline
WA_VTG_FC_REP1_STR-XKONTRH sy-vline
WA_VTG_FC_REP1_STR-XGARANT sy-vline
WA_VTG_FC_REP1_STR-XFGTYP sy-vline
WA_VTG_FC_REP1_STR-XPGTYP sy-vline
WA_VTG_FC_REP1_STR-XFGZUSTT sy-vline
WA_VTG_FC_REP1_STR-XFUNKTV sy-vline
WA_VTG_FC_REP1_STR-XFUNKTL sy-vline
WA_VTG_FC_REP1_STR-XPORTB sy-vline
WA_VTG_FC_REP1_STR-XLDEPO sy-vline
WA_VTG_FC_REP1_STR-XREFKONT sy-vline
WA_VTG_FC_REP1_STR-XREFKONT2 sy-vline
WA_VTG_FC_REP1_STR-ICON_ALARM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.