ABAP Select data from SAP table VTVERF_OUTTAB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VTVERF_OUTTAB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VTVERF_OUTTAB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VTVERF_OUTTAB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VTVERF_OUTTAB TYPE STANDARD TABLE OF VTVERF_OUTTAB,
      WA_VTVERF_OUTTAB TYPE VTVERF_OUTTAB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VTVERF_OUTTAB> TYPE VTVERF_OUTTAB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VTVERF_OUTTAB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VTVERF_OUTTAB
  INTO TABLE IT_VTVERF_OUTTAB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VTVERF_OUTTAB
*  INTO TABLE @DATA(IT_VTVERF_OUTTAB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VTVERF_OUTTAB INDEX 1 INTO DATA(WA_VTVERF_OUTTAB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VTVERF_OUTTAB ASSIGNING <VTVERF_OUTTAB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VTVERF_OUTTAB>-MANDT = 1.
<VTVERF_OUTTAB>-PRTID = 1.
<VTVERF_OUTTAB>-ETROE = 1.
<VTVERF_OUTTAB>-ETROE_BEZ = 1.
<VTVERF_OUTTAB>-BEGDT = 1.
ENDLOOP.

LOOP AT IT_VTVERF_OUTTAB INTO WA_VTVERF_OUTTAB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VTVERF_OUTTAB-ENDDT, sy-vline,
WA_VTVERF_OUTTAB-PRIO, sy-vline,
WA_VTVERF_OUTTAB-TERVKZ, sy-vline,
WA_VTVERF_OUTTAB-HITLS, sy-vline,
WA_VTVERF_OUTTAB-AVLEXBP, sy-vline,
WA_VTVERF_OUTTAB-AVLWEB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VTVERF_OUTTAB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VTVERF_OUTTAB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VTVERF_OUTTAB INTO WA_VTVERF_OUTTAB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ETROE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VTVERF_OUTTAB-ETROE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VTVERF_OUTTAB-ETROE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VTVERF_OUTTAB_STR,
MANDT TYPE STRING,
PRTID TYPE STRING,
ETROE TYPE STRING,
ETROE_BEZ TYPE STRING,
BEGDT TYPE STRING,
ENDDT TYPE STRING,
PRIO TYPE STRING,
TERVKZ TYPE STRING,
HITLS TYPE STRING,
AVLEXBP TYPE STRING,
AVLWEB TYPE STRING,
ICON_HITLISTE TYPE STRING,
ICON_VERFUEGBAR TYPE STRING,END OF T_EKKO_STR. DATA: WA_VTVERF_OUTTAB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VTVERF_OUTTAB_STR-MANDT sy-vline
WA_VTVERF_OUTTAB_STR-PRTID sy-vline
WA_VTVERF_OUTTAB_STR-ETROE sy-vline
WA_VTVERF_OUTTAB_STR-ETROE_BEZ sy-vline
WA_VTVERF_OUTTAB_STR-BEGDT sy-vline
WA_VTVERF_OUTTAB_STR-ENDDT sy-vline
WA_VTVERF_OUTTAB_STR-PRIO sy-vline
WA_VTVERF_OUTTAB_STR-TERVKZ sy-vline
WA_VTVERF_OUTTAB_STR-HITLS sy-vline
WA_VTVERF_OUTTAB_STR-AVLEXBP sy-vline
WA_VTVERF_OUTTAB_STR-AVLWEB sy-vline
WA_VTVERF_OUTTAB_STR-ICON_HITLISTE sy-vline
WA_VTVERF_OUTTAB_STR-ICON_VERFUEGBAR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.