ABAP Select data from SAP table VTVFGCF08_FLTP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP VTVFGCF08_FLTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VTVFGCF08_FLTP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the VTVFGCF08_FLTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_VTVFGCF08_FLTP TYPE STANDARD TABLE OF VTVFGCF08_FLTP, WA_VTVFGCF08_FLTP TYPE VTVFGCF08_FLTP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <VTVFGCF08_FLTP> TYPE VTVFGCF08_FLTP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_VTVFGCF08_FLTP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM VTVFGCF08_FLTP INTO TABLE IT_VTVFGCF08_FLTP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM VTVFGCF08_FLTP * INTO TABLE @DATA(IT_VTVFGCF08_FLTP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_VTVFGCF08_FLTP INDEX 1 INTO DATA(WA_VTVFGCF08_FLTP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_VTVFGCF08_FLTP ASSIGNING <VTVFGCF08_FLTP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<VTVFGCF08_FLTP>-CFKNZ = 1.
<VTVFGCF08_FLTP>-RKONDGR = 1.
<VTVFGCF08_FLTP>-SSIGN = 1.
<VTVFGCF08_FLTP>-SCWHR = 1.
<VTVFGCF08_FLTP>-BCWHR = 1.
ENDLOOP. LOOP AT IT_VTVFGCF08_FLTP INTO WA_VTVFGCF08_FLTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_VTVFGCF08_FLTP-DFAELL, sy-vline,
WA_VTVFGCF08_FLTP-DDISPO, sy-vline,
WA_VTVFGCF08_FLTP-DBERVON, sy-vline,
WA_VTVFGCF08_FLTP-DBERBIS, sy-vline,
WA_VTVFGCF08_FLTP-SZBMETH, sy-vline,
WA_VTVFGCF08_FLTP-ABASTAGE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VTVFGCF08_FLTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VTVFGCF08_FLTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VTVFGCF08_FLTP INTO WA_VTVFGCF08_FLTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VTVFGCF08_FLTP_STR,
CFKNZ TYPE STRING,
RKONDGR TYPE STRING,
SSIGN TYPE STRING,
SCWHR TYPE STRING,
BCWHR TYPE STRING,
DFAELL TYPE STRING,
DDISPO TYPE STRING,
DBERVON TYPE STRING,
DBERBIS TYPE STRING,
SZBMETH TYPE STRING,
ABASTAGE TYPE STRING,
ATAGE TYPE STRING,
CF_ASTCK TYPE STRING,
SNWHR TYPE STRING,
BNWHR TYPE STRING,
PKOND TYPE STRING,
SZSREF TYPE STRING,
SZSREFVZ TYPE STRING,
SOFFSET TYPE STRING,
SFORMREF TYPE STRING,
DZFEST TYPE STRING,
JSOFVERR TYPE STRING,
OPPZINS TYPE STRING,
FIKTKZ TYPE STRING,
SBWHR TYPE STRING,
BBWHR TYPE STRING,
XKURSKNZ TYPE STRING,
KKURS TYPE STRING,
SZINSART TYPE STRING,
FX_FIX_DATE TYPE STRING,
FX_SETTL_CRCY TYPE STRING,
BCWHR_F TYPE STRING,
BNWHR_F TYPE STRING,
BBWHR_F TYPE STRING,END OF T_EKKO_STR. DATA: WA_VTVFGCF08_FLTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VTVFGCF08_FLTP_STR-CFKNZ sy-vline
WA_VTVFGCF08_FLTP_STR-RKONDGR sy-vline
WA_VTVFGCF08_FLTP_STR-SSIGN sy-vline
WA_VTVFGCF08_FLTP_STR-SCWHR sy-vline
WA_VTVFGCF08_FLTP_STR-BCWHR sy-vline
WA_VTVFGCF08_FLTP_STR-DFAELL sy-vline
WA_VTVFGCF08_FLTP_STR-DDISPO sy-vline
WA_VTVFGCF08_FLTP_STR-DBERVON sy-vline
WA_VTVFGCF08_FLTP_STR-DBERBIS sy-vline
WA_VTVFGCF08_FLTP_STR-SZBMETH sy-vline
WA_VTVFGCF08_FLTP_STR-ABASTAGE sy-vline
WA_VTVFGCF08_FLTP_STR-ATAGE sy-vline
WA_VTVFGCF08_FLTP_STR-CF_ASTCK sy-vline
WA_VTVFGCF08_FLTP_STR-SNWHR sy-vline
WA_VTVFGCF08_FLTP_STR-BNWHR sy-vline
WA_VTVFGCF08_FLTP_STR-PKOND sy-vline
WA_VTVFGCF08_FLTP_STR-SZSREF sy-vline
WA_VTVFGCF08_FLTP_STR-SZSREFVZ sy-vline
WA_VTVFGCF08_FLTP_STR-SOFFSET sy-vline
WA_VTVFGCF08_FLTP_STR-SFORMREF sy-vline
WA_VTVFGCF08_FLTP_STR-DZFEST sy-vline
WA_VTVFGCF08_FLTP_STR-JSOFVERR sy-vline
WA_VTVFGCF08_FLTP_STR-OPPZINS sy-vline
WA_VTVFGCF08_FLTP_STR-FIKTKZ sy-vline
WA_VTVFGCF08_FLTP_STR-SBWHR sy-vline
WA_VTVFGCF08_FLTP_STR-BBWHR sy-vline
WA_VTVFGCF08_FLTP_STR-XKURSKNZ sy-vline
WA_VTVFGCF08_FLTP_STR-KKURS sy-vline
WA_VTVFGCF08_FLTP_STR-SZINSART sy-vline
WA_VTVFGCF08_FLTP_STR-FX_FIX_DATE sy-vline
WA_VTVFGCF08_FLTP_STR-FX_SETTL_CRCY sy-vline
WA_VTVFGCF08_FLTP_STR-BCWHR_F sy-vline
WA_VTVFGCF08_FLTP_STR-BNWHR_F sy-vline
WA_VTVFGCF08_FLTP_STR-BBWHR_F sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.