ABAP Select data from SAP table VXSEOS0001 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VXSEOS0001 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VXSEOS0001. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VXSEOS0001 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VXSEOS0001 TYPE STANDARD TABLE OF VXSEOS0001,
      WA_VXSEOS0001 TYPE VXSEOS0001,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VXSEOS0001> TYPE VXSEOS0001.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VXSEOS0001.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VXSEOS0001
  INTO TABLE IT_VXSEOS0001.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VXSEOS0001
*  INTO TABLE @DATA(IT_VXSEOS00012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VXSEOS0001 INDEX 1 INTO DATA(WA_VXSEOS00012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VXSEOS0001 ASSIGNING <VXSEOS0001>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VXSEOS0001>-VRSFLAG = 1.
<VXSEOS0001>-CLSNAME = 1.
<VXSEOS0001>-CMPNAME = 1.
<VXSEOS0001>-SCONAME = 1.
<VXSEOS0001>-VERSION = 1.
ENDLOOP.

LOOP AT IT_VXSEOS0001 INTO WA_VXSEOS0001.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VXSEOS0001-EDITORDER, sy-vline,
WA_VXSEOS0001-DISPID, sy-vline,
WA_VXSEOS0001-AUTHOR, sy-vline,
WA_VXSEOS0001-CREATEDON, sy-vline,
WA_VXSEOS0001-CHANGEDBY, sy-vline,
WA_VXSEOS0001-CHANGEDON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VXSEOS0001 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VXSEOS0001 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VXSEOS0001 INTO WA_VXSEOS0001. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VXSEOS0001_STR,
VRSFLAG TYPE STRING,
CLSNAME TYPE STRING,
CMPNAME TYPE STRING,
SCONAME TYPE STRING,
VERSION TYPE STRING,
EDITORDER TYPE STRING,
DISPID TYPE STRING,
AUTHOR TYPE STRING,
CREATEDON TYPE STRING,
CHANGEDBY TYPE STRING,
CHANGEDON TYPE STRING,
PARDECLTYP TYPE STRING,
PARPASSTYP TYPE STRING,
TYPTYPE TYPE STRING,
TYPE TYPE STRING,
TABLEOF TYPE STRING,
SRCROW1 TYPE STRING,
SRCCOLUMN1 TYPE STRING,
SRCROW2 TYPE STRING,
SRCCOLUMN2 TYPE STRING,
PARVALUE TYPE STRING,
PAROPTIONL TYPE STRING,
EXCDECLTYP TYPE STRING,END OF T_EKKO_STR. DATA: WA_VXSEOS0001_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VXSEOS0001_STR-VRSFLAG sy-vline
WA_VXSEOS0001_STR-CLSNAME sy-vline
WA_VXSEOS0001_STR-CMPNAME sy-vline
WA_VXSEOS0001_STR-SCONAME sy-vline
WA_VXSEOS0001_STR-VERSION sy-vline
WA_VXSEOS0001_STR-EDITORDER sy-vline
WA_VXSEOS0001_STR-DISPID sy-vline
WA_VXSEOS0001_STR-AUTHOR sy-vline
WA_VXSEOS0001_STR-CREATEDON sy-vline
WA_VXSEOS0001_STR-CHANGEDBY sy-vline
WA_VXSEOS0001_STR-CHANGEDON sy-vline
WA_VXSEOS0001_STR-PARDECLTYP sy-vline
WA_VXSEOS0001_STR-PARPASSTYP sy-vline
WA_VXSEOS0001_STR-TYPTYPE sy-vline
WA_VXSEOS0001_STR-TYPE sy-vline
WA_VXSEOS0001_STR-TABLEOF sy-vline
WA_VXSEOS0001_STR-SRCROW1 sy-vline
WA_VXSEOS0001_STR-SRCCOLUMN1 sy-vline
WA_VXSEOS0001_STR-SRCROW2 sy-vline
WA_VXSEOS0001_STR-SRCCOLUMN2 sy-vline
WA_VXSEOS0001_STR-PARVALUE sy-vline
WA_VXSEOS0001_STR-PAROPTIONL sy-vline
WA_VXSEOS0001_STR-EXCDECLTYP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.