ABAP Select data from SAP table WCVITX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WCVITX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WCVITX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WCVITX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WCVITX TYPE STANDARD TABLE OF WCVITX,
      WA_WCVITX TYPE WCVITX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WCVITX> TYPE WCVITX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WCVITX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WCVITX
  INTO TABLE IT_WCVITX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WCVITX
*  INTO TABLE @DATA(IT_WCVITX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WCVITX INDEX 1 INTO DATA(WA_WCVITX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WCVITX ASSIGNING <WCVITX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WCVITX>-MANDT = 1.
<WCVITX>-WCNR = 1.
<WCVITX>-WCITM = 1.
<WCVITX>-OBJNR = 1.
<WCVITX>-ITMTYP = 1.
ENDLOOP.

LOOP AT IT_WCVITX INTO WA_WCVITX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WCVITX-SEQ, sy-vline,
WA_WCVITX-PRED, sy-vline,
WA_WCVITX-SUCC, sy-vline,
WA_WCVITX-CCTYP, sy-vline,
WA_WCVITX-STXT, sy-vline,
WA_WCVITX-TGGRP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WCVITX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WCVITX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WCVITX INTO WA_WCVITX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field WCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WCVITX-WCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCVITX-WCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TGNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WCVITX-TGNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCVITX-TGNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WCVITX-UNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCVITX-UNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR_INT CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_WCVITX-TPLNR_INT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCVITX-TPLNR_INT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WCVITX_STR,
MANDT TYPE STRING,
WCNR TYPE STRING,
WCITM TYPE STRING,
OBJNR TYPE STRING,
ITMTYP TYPE STRING,
SEQ TYPE STRING,
PRED TYPE STRING,
SUCC TYPE STRING,
CCTYP TYPE STRING,
STXT TYPE STRING,
TGGRP TYPE STRING,
TGSTEP TYPE STRING,
TGPROC TYPE STRING,
TGTYP TYPE STRING,
TGSEQ TYPE STRING,
TGTXT TYPE STRING,
UNSTEP TYPE STRING,
UNPROC TYPE STRING,
UNTYP TYPE STRING,
UNSEQ TYPE STRING,
UNTXT TYPE STRING,
PHBLFLG TYPE STRING,
PHBLTYP TYPE STRING,
PHBLNR TYPE STRING,
TGFLG TYPE STRING,
TGFORM TYPE STRING,
TGNR TYPE STRING,
UNFORM TYPE STRING,
UNNR TYPE STRING,
CONTROL TYPE STRING,
LOCATION TYPE STRING,
LFLG TYPE STRING,
DOCFLG TYPE STRING,
REFOBJ TYPE STRING,
CCOBJ TYPE STRING,
TPLNR_INT TYPE STRING,END OF T_EKKO_STR. DATA: WA_WCVITX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WCVITX_STR-MANDT sy-vline
WA_WCVITX_STR-WCNR sy-vline
WA_WCVITX_STR-WCITM sy-vline
WA_WCVITX_STR-OBJNR sy-vline
WA_WCVITX_STR-ITMTYP sy-vline
WA_WCVITX_STR-SEQ sy-vline
WA_WCVITX_STR-PRED sy-vline
WA_WCVITX_STR-SUCC sy-vline
WA_WCVITX_STR-CCTYP sy-vline
WA_WCVITX_STR-STXT sy-vline
WA_WCVITX_STR-TGGRP sy-vline
WA_WCVITX_STR-TGSTEP sy-vline
WA_WCVITX_STR-TGPROC sy-vline
WA_WCVITX_STR-TGTYP sy-vline
WA_WCVITX_STR-TGSEQ sy-vline
WA_WCVITX_STR-TGTXT sy-vline
WA_WCVITX_STR-UNSTEP sy-vline
WA_WCVITX_STR-UNPROC sy-vline
WA_WCVITX_STR-UNTYP sy-vline
WA_WCVITX_STR-UNSEQ sy-vline
WA_WCVITX_STR-UNTXT sy-vline
WA_WCVITX_STR-PHBLFLG sy-vline
WA_WCVITX_STR-PHBLTYP sy-vline
WA_WCVITX_STR-PHBLNR sy-vline
WA_WCVITX_STR-TGFLG sy-vline
WA_WCVITX_STR-TGFORM sy-vline
WA_WCVITX_STR-TGNR sy-vline
WA_WCVITX_STR-UNFORM sy-vline
WA_WCVITX_STR-UNNR sy-vline
WA_WCVITX_STR-CONTROL sy-vline
WA_WCVITX_STR-LOCATION sy-vline
WA_WCVITX_STR-LFLG sy-vline
WA_WCVITX_STR-DOCFLG sy-vline
WA_WCVITX_STR-REFOBJ sy-vline
WA_WCVITX_STR-CCOBJ sy-vline
WA_WCVITX_STR-TPLNR_INT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.