ABAP Select data from SAP table WDY_MD_COMPONENT_META_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP WDY_MD_COMPONENT_META_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WDY_MD_COMPONENT_META_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the WDY_MD_COMPONENT_META_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_WDY_MD_COMPONENT_META_DATA TYPE STANDARD TABLE OF WDY_MD_COMPONENT_META_DATA, WA_WDY_MD_COMPONENT_META_DATA TYPE WDY_MD_COMPONENT_META_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <WDY_MD_COMPONENT_META_DATA> TYPE WDY_MD_COMPONENT_META_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_WDY_MD_COMPONENT_META_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM WDY_MD_COMPONENT_META_DATA INTO TABLE IT_WDY_MD_COMPONENT_META_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM WDY_MD_COMPONENT_META_DATA * INTO TABLE @DATA(IT_WDY_MD_COMPONENT_META_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_WDY_MD_COMPONENT_META_DATA INDEX 1 INTO DATA(WA_WDY_MD_COMPONENT_META_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_WDY_MD_COMPONENT_META_DATA ASSIGNING <WDY_MD_COMPONENT_META_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<WDY_MD_COMPONENT_META_DATA>-DEFINITION = 1.
<WDY_MD_COMPONENT_META_DATA>-COMPONENT_NAME = 1.
<WDY_MD_COMPONENT_META_DATA>-VERSION = 1.
<WDY_MD_COMPONENT_META_DATA>-TYPE = 1.
<WDY_MD_COMPONENT_META_DATA>-CMP_CONTROLLER = 1.
ENDLOOP. LOOP AT IT_WDY_MD_COMPONENT_META_DATA INTO WA_WDY_MD_COMPONENT_META_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_WDY_MD_COMPONENT_META_DATA-CONFIG_CTLR, sy-vline,
WA_WDY_MD_COMPONENT_META_DATA-CMP_INTERFACE, sy-vline,
WA_WDY_MD_COMPONENT_META_DATA-DISPLAY_NAME, sy-vline,
WA_WDY_MD_COMPONENT_META_DATA-MODULE_POOL_NAME, sy-vline,
WA_WDY_MD_COMPONENT_META_DATA-AUTHOR, sy-vline,
WA_WDY_MD_COMPONENT_META_DATA-CREATEDON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WDY_MD_COMPONENT_META_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WDY_MD_COMPONENT_META_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WDY_MD_COMPONENT_META_DATA INTO WA_WDY_MD_COMPONENT_META_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WDY_MD_COMPONENT_META_DATA_STR,
DEFINITION TYPE STRING,
COMPONENT_NAME TYPE STRING,
VERSION TYPE STRING,
TYPE TYPE STRING,
CMP_CONTROLLER TYPE STRING,
CONFIG_CTLR TYPE STRING,
CMP_INTERFACE TYPE STRING,
DISPLAY_NAME TYPE STRING,
MODULE_POOL_NAME TYPE STRING,
AUTHOR TYPE STRING,
CREATEDON TYPE STRING,
CHANGEDBY TYPE STRING,
CHANGEDON TYPE STRING,
GENDATE TYPE STRING,
GENTIME TYPE STRING,
NO_ACC_CHECKS TYPE STRING,
CONFIG_EDITOR TYPE STRING,
CONFIG_HIDDEN TYPE STRING,
CONFIG_EXPL_PROP TYPE STRING,
CONFIG_IMPL_PROP TYPE STRING,
P13N_EXPL_PROP TYPE STRING,
P13N_IMPL_PROP TYPE STRING,
ADDITIONAL_PROPS TYPE STRING,
CAN_HDL_VARIANTS TYPE STRING,
ASSISTANCE_CLASS TYPE STRING,
DESCRIPTIONS TYPE STRING,
COMPONENT_USAGES TYPE STRING,
WINDOWS TYPE STRING,
WINDOW_TEXTS TYPE STRING,
NAVIGATION_LINKS TYPE STRING,
NAVIGATION_TARGET_REFS TYPE STRING,
VSH_NODES TYPE STRING,
VSH_PLACEHOLDERS TYPE STRING,
VIEWSET_PROPERTIES TYPE STRING,
INTERFACE_IMPLEMENTINGS TYPE STRING,
LIBRARY_USAGES TYPE STRING,
EXT_CTLR_USAGES TYPE STRING,
EXT_CTX_MAPPINGS TYPE STRING,END OF T_EKKO_STR. DATA: WA_WDY_MD_COMPONENT_META_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-DEFINITION sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-COMPONENT_NAME sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-VERSION sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-TYPE sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CMP_CONTROLLER sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CONFIG_CTLR sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CMP_INTERFACE sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-DISPLAY_NAME sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-MODULE_POOL_NAME sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-AUTHOR sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CREATEDON sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CHANGEDBY sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CHANGEDON sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-GENDATE sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-GENTIME sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-NO_ACC_CHECKS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CONFIG_EDITOR sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CONFIG_HIDDEN sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CONFIG_EXPL_PROP sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CONFIG_IMPL_PROP sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-P13N_EXPL_PROP sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-P13N_IMPL_PROP sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-ADDITIONAL_PROPS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-CAN_HDL_VARIANTS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-ASSISTANCE_CLASS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-DESCRIPTIONS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-COMPONENT_USAGES sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-WINDOWS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-WINDOW_TEXTS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-NAVIGATION_LINKS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-NAVIGATION_TARGET_REFS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-VSH_NODES sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-VSH_PLACEHOLDERS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-VIEWSET_PROPERTIES sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-INTERFACE_IMPLEMENTINGS sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-LIBRARY_USAGES sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-EXT_CTLR_USAGES sy-vline
WA_WDY_MD_COMPONENT_META_DATA_STR-EXT_CTX_MAPPINGS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.