ABAP Select data from SAP table WSALMTCUSTWR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WSALMTCUSTWR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WSALMTCUSTWR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WSALMTCUSTWR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WSALMTCUSTWR TYPE STANDARD TABLE OF WSALMTCUSTWR,
      WA_WSALMTCUSTWR TYPE WSALMTCUSTWR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WSALMTCUSTWR> TYPE WSALMTCUSTWR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WSALMTCUSTWR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WSALMTCUSTWR
  INTO TABLE IT_WSALMTCUSTWR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WSALMTCUSTWR
*  INTO TABLE @DATA(IT_WSALMTCUSTWR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WSALMTCUSTWR INDEX 1 INTO DATA(WA_WSALMTCUSTWR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WSALMTCUSTWR ASSIGNING <WSALMTCUSTWR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WSALMTCUSTWR>-CONTROLLER = 1.
<WSALMTCUSTWR>-TID = 1.
<WSALMTCUSTWR>-CONTROLLER = 1.
<WSALMTCUSTWR>-MTSYSID = 1.
<WSALMTCUSTWR>-MTMCNAME = 1.
ENDLOOP.

LOOP AT IT_WSALMTCUSTWR INTO WA_WSALMTCUSTWR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WSALMTCUSTWR-MTNUMRANGE, sy-vline,
WA_WSALMTCUSTWR-MTUID, sy-vline,
WA_WSALMTCUSTWR-MTCLASS, sy-vline,
WA_WSALMTCUSTWR-MTINDEX, sy-vline,
WA_WSALMTCUSTWR-EXTINDEX, sy-vline,
WA_WSALMTCUSTWR-GENERAL_CUST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WSALMTCUSTWR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WSALMTCUSTWR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WSALMTCUSTWR INTO WA_WSALMTCUSTWR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WSALMTCUSTWR_STR,
CONTROLLER TYPE STRING,
TID TYPE STRING,
CONTROLLER TYPE STRING,
MTSYSID TYPE STRING,
MTMCNAME TYPE STRING,
MTNUMRANGE TYPE STRING,
MTUID TYPE STRING,
MTCLASS TYPE STRING,
MTINDEX TYPE STRING,
EXTINDEX TYPE STRING,
GENERAL_CUST TYPE STRING,
CONTROLLER TYPE STRING,
CUST_STATUS TYPE STRING,
USECLASS TYPE STRING,
SEVERITY TYPE STRING,
STAT_RECORD TYPE STRING,
VISIBILITY_LEVEL TYPE STRING,
TYPE_OF_ALERTS_TO_KEEP TYPE STRING,
NUM_OF_ALERTS_TO_KEEP TYPE STRING,
COLL_INTERVAL TYPE STRING,
INACTIVE_AFTER TYPE STRING,
WARMUPTIME TYPE STRING,
TEXT_CLASS TYPE STRING,
TEXT_ID TYPE STRING,
ATTR_GROUP_NAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_WSALMTCUSTWR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WSALMTCUSTWR_STR-CONTROLLER sy-vline
WA_WSALMTCUSTWR_STR-TID sy-vline
WA_WSALMTCUSTWR_STR-CONTROLLER sy-vline
WA_WSALMTCUSTWR_STR-MTSYSID sy-vline
WA_WSALMTCUSTWR_STR-MTMCNAME sy-vline
WA_WSALMTCUSTWR_STR-MTNUMRANGE sy-vline
WA_WSALMTCUSTWR_STR-MTUID sy-vline
WA_WSALMTCUSTWR_STR-MTCLASS sy-vline
WA_WSALMTCUSTWR_STR-MTINDEX sy-vline
WA_WSALMTCUSTWR_STR-EXTINDEX sy-vline
WA_WSALMTCUSTWR_STR-GENERAL_CUST sy-vline
WA_WSALMTCUSTWR_STR-CONTROLLER sy-vline
WA_WSALMTCUSTWR_STR-CUST_STATUS sy-vline
WA_WSALMTCUSTWR_STR-USECLASS sy-vline
WA_WSALMTCUSTWR_STR-SEVERITY sy-vline
WA_WSALMTCUSTWR_STR-STAT_RECORD sy-vline
WA_WSALMTCUSTWR_STR-VISIBILITY_LEVEL sy-vline
WA_WSALMTCUSTWR_STR-TYPE_OF_ALERTS_TO_KEEP sy-vline
WA_WSALMTCUSTWR_STR-NUM_OF_ALERTS_TO_KEEP sy-vline
WA_WSALMTCUSTWR_STR-COLL_INTERVAL sy-vline
WA_WSALMTCUSTWR_STR-INACTIVE_AFTER sy-vline
WA_WSALMTCUSTWR_STR-WARMUPTIME sy-vline
WA_WSALMTCUSTWR_STR-TEXT_CLASS sy-vline
WA_WSALMTCUSTWR_STR-TEXT_ID sy-vline
WA_WSALMTCUSTWR_STR-ATTR_GROUP_NAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.