ABAP Select data from SAP table WSRECORD_CALL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP WSRECORD_CALL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WSRECORD_CALL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the WSRECORD_CALL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_WSRECORD_CALL TYPE STANDARD TABLE OF WSRECORD_CALL, WA_WSRECORD_CALL TYPE WSRECORD_CALL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <WSRECORD_CALL> TYPE WSRECORD_CALL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_WSRECORD_CALL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM WSRECORD_CALL INTO TABLE IT_WSRECORD_CALL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM WSRECORD_CALL * INTO TABLE @DATA(IT_WSRECORD_CALL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_WSRECORD_CALL INDEX 1 INTO DATA(WA_WSRECORD_CALL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_WSRECORD_CALL ASSIGNING <WSRECORD_CALL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<WSRECORD_CALL>-CONTROLLER = 1.
<WSRECORD_CALL>-COMPONENT_TYPE = 1.
<WSRECORD_CALL>-COMPONENT_NAME = 1.
<WSRECORD_CALL>-DESTINATION = 1.
<WSRECORD_CALL>-CALL_TIME = 1.
ENDLOOP. LOOP AT IT_WSRECORD_CALL INTO WA_WSRECORD_CALL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_WSRECORD_CALL-RECEIVE_TIME, sy-vline,
WA_WSRECORD_CALL-SENT_BYTES, sy-vline,
WA_WSRECORD_CALL-RECEIVED_BYTES, sy-vline,
WA_WSRECORD_CALL-NUMBER_OF_CALLS, sy-vline,
WA_WSRECORD_CALL-ADDITIONAL_INFO, sy-vline,
ENDLOOP. *Add any further fields from structure WA_WSRECORD_CALL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WSRECORD_CALL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WSRECORD_CALL INTO WA_WSRECORD_CALL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WSRECORD_CALL_STR,
CONTROLLER TYPE STRING,
COMPONENT_TYPE TYPE STRING,
COMPONENT_NAME TYPE STRING,
DESTINATION TYPE STRING,
CALL_TIME TYPE STRING,
RECEIVE_TIME TYPE STRING,
SENT_BYTES TYPE STRING,
RECEIVED_BYTES TYPE STRING,
NUMBER_OF_CALLS TYPE STRING,
ADDITIONAL_INFO TYPE STRING,END OF T_EKKO_STR. DATA: WA_WSRECORD_CALL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WSRECORD_CALL_STR-CONTROLLER sy-vline
WA_WSRECORD_CALL_STR-COMPONENT_TYPE sy-vline
WA_WSRECORD_CALL_STR-COMPONENT_NAME sy-vline
WA_WSRECORD_CALL_STR-DESTINATION sy-vline
WA_WSRECORD_CALL_STR-CALL_TIME sy-vline
WA_WSRECORD_CALL_STR-RECEIVE_TIME sy-vline
WA_WSRECORD_CALL_STR-SENT_BYTES sy-vline
WA_WSRECORD_CALL_STR-RECEIVED_BYTES sy-vline
WA_WSRECORD_CALL_STR-NUMBER_OF_CALLS sy-vline
WA_WSRECORD_CALL_STR-ADDITIONAL_INFO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.