ABAP Select data from SAP table WTY_KOMB_ZUSATZ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WTY_KOMB_ZUSATZ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WTY_KOMB_ZUSATZ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WTY_KOMB_ZUSATZ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WTY_KOMB_ZUSATZ TYPE STANDARD TABLE OF WTY_KOMB_ZUSATZ,
      WA_WTY_KOMB_ZUSATZ TYPE WTY_KOMB_ZUSATZ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WTY_KOMB_ZUSATZ> TYPE WTY_KOMB_ZUSATZ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WTY_KOMB_ZUSATZ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WTY_KOMB_ZUSATZ
  INTO TABLE IT_WTY_KOMB_ZUSATZ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WTY_KOMB_ZUSATZ
*  INTO TABLE @DATA(IT_WTY_KOMB_ZUSATZ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WTY_KOMB_ZUSATZ INDEX 1 INTO DATA(WA_WTY_KOMB_ZUSATZ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WTY_KOMB_ZUSATZ ASSIGNING <WTY_KOMB_ZUSATZ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WTY_KOMB_ZUSATZ>-CLMNO = 1.
<WTY_KOMB_ZUSATZ>-CLMTY = 1.
<WTY_KOMB_ZUSATZ>-REFDT = 1.
<WTY_KOMB_ZUSATZ>-REFNO = 1.
<WTY_KOMB_ZUSATZ>-OLDCN = 1.
ENDLOOP.

LOOP AT IT_WTY_KOMB_ZUSATZ INTO WA_WTY_KOMB_ZUSATZ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WTY_KOMB_ZUSATZ-AUTNO, sy-vline,
WA_WTY_KOMB_ZUSATZ-AUTNA, sy-vline,
WA_WTY_KOMB_ZUSATZ-CLERK, sy-vline,
WA_WTY_KOMB_ZUSATZ-RELTY, sy-vline,
WA_WTY_KOMB_ZUSATZ-RELOB, sy-vline,
WA_WTY_KOMB_ZUSATZ-RELOT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WTY_KOMB_ZUSATZ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WTY_KOMB_ZUSATZ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WTY_KOMB_ZUSATZ INTO WA_WTY_KOMB_ZUSATZ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CLMNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_KOMB_ZUSATZ-CLMNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_KOMB_ZUSATZ-CLMNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OLDCN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_KOMB_ZUSATZ-OLDCN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_KOMB_ZUSATZ-OLDCN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_WTY_KOMB_ZUSATZ-PARVW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_KOMB_ZUSATZ-PARVW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_KOMB_ZUSATZ-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_KOMB_ZUSATZ-QMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field V_PARNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_KOMB_ZUSATZ-V_PARNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_KOMB_ZUSATZ-V_PARNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field V_PARVW CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_WTY_KOMB_ZUSATZ-V_PARVW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_KOMB_ZUSATZ-V_PARVW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSK CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_WTY_KOMB_ZUSATZ-KURSK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_KOMB_ZUSATZ-KURSK.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WTY_KOMB_ZUSATZ_STR,
CLMNO TYPE STRING,
CLMTY TYPE STRING,
REFDT TYPE STRING,
REFNO TYPE STRING,
OLDCN TYPE STRING,
AUTNO TYPE STRING,
AUTNA TYPE STRING,
CLERK TYPE STRING,
RELTY TYPE STRING,
RELOB TYPE STRING,
RELOT TYPE STRING,
RELOB_EXT TYPE STRING,
RELDT TYPE STRING,
PARVW TYPE STRING,
ASTATE TYPE STRING,
QMNUM TYPE STRING,
VERSN TYPE STRING,
KATEG TYPE STRING,
V_REJCD TYPE STRING,
V_PARNR TYPE STRING,
V_PARVW TYPE STRING,
REFKT TYPE STRING,
REFNR TYPE STRING,
AKTIV TYPE STRING,
V_CRNCY TYPE STRING,
KURSK TYPE STRING,
PRICING_OK TYPE STRING,
NEW_VERSION TYPE STRING,
COMPSEND TYPE STRING,
NRART TYPE STRING,END OF T_EKKO_STR. DATA: WA_WTY_KOMB_ZUSATZ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WTY_KOMB_ZUSATZ_STR-CLMNO sy-vline
WA_WTY_KOMB_ZUSATZ_STR-CLMTY sy-vline
WA_WTY_KOMB_ZUSATZ_STR-REFDT sy-vline
WA_WTY_KOMB_ZUSATZ_STR-REFNO sy-vline
WA_WTY_KOMB_ZUSATZ_STR-OLDCN sy-vline
WA_WTY_KOMB_ZUSATZ_STR-AUTNO sy-vline
WA_WTY_KOMB_ZUSATZ_STR-AUTNA sy-vline
WA_WTY_KOMB_ZUSATZ_STR-CLERK sy-vline
WA_WTY_KOMB_ZUSATZ_STR-RELTY sy-vline
WA_WTY_KOMB_ZUSATZ_STR-RELOB sy-vline
WA_WTY_KOMB_ZUSATZ_STR-RELOT sy-vline
WA_WTY_KOMB_ZUSATZ_STR-RELOB_EXT sy-vline
WA_WTY_KOMB_ZUSATZ_STR-RELDT sy-vline
WA_WTY_KOMB_ZUSATZ_STR-PARVW sy-vline
WA_WTY_KOMB_ZUSATZ_STR-ASTATE sy-vline
WA_WTY_KOMB_ZUSATZ_STR-QMNUM sy-vline
WA_WTY_KOMB_ZUSATZ_STR-VERSN sy-vline
WA_WTY_KOMB_ZUSATZ_STR-KATEG sy-vline
WA_WTY_KOMB_ZUSATZ_STR-V_REJCD sy-vline
WA_WTY_KOMB_ZUSATZ_STR-V_PARNR sy-vline
WA_WTY_KOMB_ZUSATZ_STR-V_PARVW sy-vline
WA_WTY_KOMB_ZUSATZ_STR-REFKT sy-vline
WA_WTY_KOMB_ZUSATZ_STR-REFNR sy-vline
WA_WTY_KOMB_ZUSATZ_STR-AKTIV sy-vline
WA_WTY_KOMB_ZUSATZ_STR-V_CRNCY sy-vline
WA_WTY_KOMB_ZUSATZ_STR-KURSK sy-vline
WA_WTY_KOMB_ZUSATZ_STR-PRICING_OK sy-vline
WA_WTY_KOMB_ZUSATZ_STR-NEW_VERSION sy-vline
WA_WTY_KOMB_ZUSATZ_STR-COMPSEND sy-vline
WA_WTY_KOMB_ZUSATZ_STR-NRART sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.