ABAP Select data from SAP table WTY_PNH_DYNPRO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WTY_PNH_DYNPRO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WTY_PNH_DYNPRO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WTY_PNH_DYNPRO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WTY_PNH_DYNPRO TYPE STANDARD TABLE OF WTY_PNH_DYNPRO,
      WA_WTY_PNH_DYNPRO TYPE WTY_PNH_DYNPRO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WTY_PNH_DYNPRO> TYPE WTY_PNH_DYNPRO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WTY_PNH_DYNPRO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WTY_PNH_DYNPRO
  INTO TABLE IT_WTY_PNH_DYNPRO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WTY_PNH_DYNPRO
*  INTO TABLE @DATA(IT_WTY_PNH_DYNPRO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WTY_PNH_DYNPRO INDEX 1 INTO DATA(WA_WTY_PNH_DYNPRO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WTY_PNH_DYNPRO ASSIGNING <WTY_PNH_DYNPRO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WTY_PNH_DYNPRO>-PNAME = 1.
<WTY_PNH_DYNPRO>-PNTYPE = 1.
<WTY_PNH_DYNPRO>-APPLOBJ_TYPE = 1.
<WTY_PNH_DYNPRO>-MANDT = 1.
<WTY_PNH_DYNPRO>-PNGUID = 1.
ENDLOOP.

LOOP AT IT_WTY_PNH_DYNPRO INTO WA_WTY_PNH_DYNPRO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WTY_PNH_DYNPRO-PNCNT, sy-vline,
WA_WTY_PNH_DYNPRO-PNTXCNT, sy-vline,
WA_WTY_PNH_DYNPRO-CLMNO, sy-vline,
WA_WTY_PNH_DYNPRO-CLMTY, sy-vline,
WA_WTY_PNH_DYNPRO-REFDT, sy-vline,
WA_WTY_PNH_DYNPRO-REFNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WTY_PNH_DYNPRO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WTY_PNH_DYNPRO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WTY_PNH_DYNPRO INTO WA_WTY_PNH_DYNPRO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CLMNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-CLMNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-CLMNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OLDCN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-OLDCN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-OLDCN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-PARNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-PARNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-PARVW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-PARVW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-QMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERNO CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-SERNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-SERNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERNO2 CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-SERNO2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-SERNO2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-ADRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-ADRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LUNIT, internal->external for field D_UNIT CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-D_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-D_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TDSPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_WTY_PNH_DYNPRO-TDSPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNH_DYNPRO-TDSPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WTY_PNH_DYNPRO_STR,
PNAME TYPE STRING,
PNTYPE TYPE STRING,
APPLOBJ_TYPE TYPE STRING,
MANDT TYPE STRING,
PNGUID TYPE STRING,
PNCNT TYPE STRING,
PNTXCNT TYPE STRING,
CLMNO TYPE STRING,
CLMTY TYPE STRING,
REFDT TYPE STRING,
REFNO TYPE STRING,
OLDCN TYPE STRING,
AUTNO TYPE STRING,
AUTNA TYPE STRING,
CLERK TYPE STRING,
RELTY TYPE STRING,
RELOB_EXT TYPE STRING,
RELOB TYPE STRING,
RELOT TYPE STRING,
RELDT TYPE STRING,
PARNR TYPE STRING,
PARVW TYPE STRING,
OBJNR TYPE STRING,
ASTATE TYPE STRING,
WERKS TYPE STRING,
QMNUM TYPE STRING,
LOG_HANDLE TYPE STRING,
LOG_MESSAGE TYPE STRING,
CLMGRP TYPE STRING,
RESULT_OUT_MWTY TYPE STRING,
RESULT_IN_MWTY TYPE STRING,
RELTY2 TYPE STRING,
RELOB_EXT2 TYPE STRING,
RELOB2 TYPE STRING,
SERNO TYPE STRING,
SERNO2 TYPE STRING,
CBACTIONDT TYPE STRING,
OR_DUMMY TYPE STRING,
CLOSE_DATE TYPE STRING,
ARCHIV_FLAG TYPE STRING,
H_DUMMY TYPE STRING,
CTR_MODE TYPE STRING,
NEW_HEADER TYPE STRING,
MANUAL TYPE STRING,
CLOSED TYPE STRING,
TIMSTMP TYPE STRING,
CREADAT TYPE STRING,
CREABY TYPE STRING,
CHNGDAT TYPE STRING,
CHNGBY TYPE STRING,
H_PNTEXT TYPE STRING,
LOGSYS TYPE STRING,
CREATIME TYPE STRING,
CLMTY_DES TYPE STRING,
MODTX TYPE STRING,
EQUNR TYPE STRING,
PARTX TYPE STRING,
ADRNR TYPE STRING,
PNTEXT TYPE STRING,
CRNCY TYPE STRING,
VALIC TYPE STRING,
VALIC_CRNCY TYPE STRING,
VALOV TYPE STRING,
VALOV_CRNCY TYPE STRING,
VALIV TYPE STRING,
VALIV_CRNCY TYPE STRING,
VALOC TYPE STRING,
VALOC_CRNCY TYPE STRING,
ASTATE_TXT TYPE STRING,
DISTANCE TYPE STRING,
D_UNIT TYPE STRING,
TDSPRAS TYPE STRING,
TEXT_EXISTS TYPE STRING,
FI_DOC_EXIST TYPE STRING,
QMART TYPE STRING,
OBJCT_TXT TYPE STRING,
CLMGRPTX TYPE STRING,
CHANGE_FLAG TYPE STRING,
MATNR_SERNO TYPE STRING,
MATNR_SERNO2 TYPE STRING,
OBJCT_TXT2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_WTY_PNH_DYNPRO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WTY_PNH_DYNPRO_STR-PNAME sy-vline
WA_WTY_PNH_DYNPRO_STR-PNTYPE sy-vline
WA_WTY_PNH_DYNPRO_STR-APPLOBJ_TYPE sy-vline
WA_WTY_PNH_DYNPRO_STR-MANDT sy-vline
WA_WTY_PNH_DYNPRO_STR-PNGUID sy-vline
WA_WTY_PNH_DYNPRO_STR-PNCNT sy-vline
WA_WTY_PNH_DYNPRO_STR-PNTXCNT sy-vline
WA_WTY_PNH_DYNPRO_STR-CLMNO sy-vline
WA_WTY_PNH_DYNPRO_STR-CLMTY sy-vline
WA_WTY_PNH_DYNPRO_STR-REFDT sy-vline
WA_WTY_PNH_DYNPRO_STR-REFNO sy-vline
WA_WTY_PNH_DYNPRO_STR-OLDCN sy-vline
WA_WTY_PNH_DYNPRO_STR-AUTNO sy-vline
WA_WTY_PNH_DYNPRO_STR-AUTNA sy-vline
WA_WTY_PNH_DYNPRO_STR-CLERK sy-vline
WA_WTY_PNH_DYNPRO_STR-RELTY sy-vline
WA_WTY_PNH_DYNPRO_STR-RELOB_EXT sy-vline
WA_WTY_PNH_DYNPRO_STR-RELOB sy-vline
WA_WTY_PNH_DYNPRO_STR-RELOT sy-vline
WA_WTY_PNH_DYNPRO_STR-RELDT sy-vline
WA_WTY_PNH_DYNPRO_STR-PARNR sy-vline
WA_WTY_PNH_DYNPRO_STR-PARVW sy-vline
WA_WTY_PNH_DYNPRO_STR-OBJNR sy-vline
WA_WTY_PNH_DYNPRO_STR-ASTATE sy-vline
WA_WTY_PNH_DYNPRO_STR-WERKS sy-vline
WA_WTY_PNH_DYNPRO_STR-QMNUM sy-vline
WA_WTY_PNH_DYNPRO_STR-LOG_HANDLE sy-vline
WA_WTY_PNH_DYNPRO_STR-LOG_MESSAGE sy-vline
WA_WTY_PNH_DYNPRO_STR-CLMGRP sy-vline
WA_WTY_PNH_DYNPRO_STR-RESULT_OUT_MWTY sy-vline
WA_WTY_PNH_DYNPRO_STR-RESULT_IN_MWTY sy-vline
WA_WTY_PNH_DYNPRO_STR-RELTY2 sy-vline
WA_WTY_PNH_DYNPRO_STR-RELOB_EXT2 sy-vline
WA_WTY_PNH_DYNPRO_STR-RELOB2 sy-vline
WA_WTY_PNH_DYNPRO_STR-SERNO sy-vline
WA_WTY_PNH_DYNPRO_STR-SERNO2 sy-vline
WA_WTY_PNH_DYNPRO_STR-CBACTIONDT sy-vline
WA_WTY_PNH_DYNPRO_STR-OR_DUMMY sy-vline
WA_WTY_PNH_DYNPRO_STR-CLOSE_DATE sy-vline
WA_WTY_PNH_DYNPRO_STR-ARCHIV_FLAG sy-vline
WA_WTY_PNH_DYNPRO_STR-H_DUMMY sy-vline
WA_WTY_PNH_DYNPRO_STR-CTR_MODE sy-vline
WA_WTY_PNH_DYNPRO_STR-NEW_HEADER sy-vline
WA_WTY_PNH_DYNPRO_STR-MANUAL sy-vline
WA_WTY_PNH_DYNPRO_STR-CLOSED sy-vline
WA_WTY_PNH_DYNPRO_STR-TIMSTMP sy-vline
WA_WTY_PNH_DYNPRO_STR-CREADAT sy-vline
WA_WTY_PNH_DYNPRO_STR-CREABY sy-vline
WA_WTY_PNH_DYNPRO_STR-CHNGDAT sy-vline
WA_WTY_PNH_DYNPRO_STR-CHNGBY sy-vline
WA_WTY_PNH_DYNPRO_STR-H_PNTEXT sy-vline
WA_WTY_PNH_DYNPRO_STR-LOGSYS sy-vline
WA_WTY_PNH_DYNPRO_STR-CREATIME sy-vline
WA_WTY_PNH_DYNPRO_STR-CLMTY_DES sy-vline
WA_WTY_PNH_DYNPRO_STR-MODTX sy-vline
WA_WTY_PNH_DYNPRO_STR-EQUNR sy-vline
WA_WTY_PNH_DYNPRO_STR-PARTX sy-vline
WA_WTY_PNH_DYNPRO_STR-ADRNR sy-vline
WA_WTY_PNH_DYNPRO_STR-PNTEXT sy-vline
WA_WTY_PNH_DYNPRO_STR-CRNCY sy-vline
WA_WTY_PNH_DYNPRO_STR-VALIC sy-vline
WA_WTY_PNH_DYNPRO_STR-VALIC_CRNCY sy-vline
WA_WTY_PNH_DYNPRO_STR-VALOV sy-vline
WA_WTY_PNH_DYNPRO_STR-VALOV_CRNCY sy-vline
WA_WTY_PNH_DYNPRO_STR-VALIV sy-vline
WA_WTY_PNH_DYNPRO_STR-VALIV_CRNCY sy-vline
WA_WTY_PNH_DYNPRO_STR-VALOC sy-vline
WA_WTY_PNH_DYNPRO_STR-VALOC_CRNCY sy-vline
WA_WTY_PNH_DYNPRO_STR-ASTATE_TXT sy-vline
WA_WTY_PNH_DYNPRO_STR-DISTANCE sy-vline
WA_WTY_PNH_DYNPRO_STR-D_UNIT sy-vline
WA_WTY_PNH_DYNPRO_STR-TDSPRAS sy-vline
WA_WTY_PNH_DYNPRO_STR-TEXT_EXISTS sy-vline
WA_WTY_PNH_DYNPRO_STR-FI_DOC_EXIST sy-vline
WA_WTY_PNH_DYNPRO_STR-QMART sy-vline
WA_WTY_PNH_DYNPRO_STR-OBJCT_TXT sy-vline
WA_WTY_PNH_DYNPRO_STR-CLMGRPTX sy-vline
WA_WTY_PNH_DYNPRO_STR-CHANGE_FLAG sy-vline
WA_WTY_PNH_DYNPRO_STR-MATNR_SERNO sy-vline
WA_WTY_PNH_DYNPRO_STR-MATNR_SERNO2 sy-vline
WA_WTY_PNH_DYNPRO_STR-OBJCT_TXT2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.